English
Language : 

LU1-033-1500 Datasheet, PDF (1/1 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Cable assembly
Technical Data Sheet
Cable assembly
RPC-2.92 Plug / RPC-2.92 Jack – RTK 106
LU1-033-XXX
All dimensions are in mm; tolerances: ± 3mm for A ≤ 300 mm; ± 1% for A > 300 mm
Available variants
Type
max. Insertion loss at 40 GHz
Marking
Weight (g) / pce
ROSENBERGER YYYY-WW
LU1-033-XXX
≤ 0.00285 dB/mm * A mm + 0.6 dB LU1-033-XXX
FAC-RRRRRRR
ssss
0.0361 g/mm * A mm + 27 g
XXX – length in mm = A
Standard lengths are 500 / 1000 /1500 /2000mm
WW – week
YYYY – year
ssss – serial no.
FAC – Factory Code
RRRRRRR – lot nr.
Note:
max. Insertion Loss:
First constant = Cable attenuation in dB /mm; Second Constant = Connector left and Connector right +needed Adaptor
Weight:
First constant = Cable- and Armour- weight per mm; Second Constant = Connector left and Connector right weight per pce
Assembly parts
Connector left
Connector right
Cable
RPC-2.92 plug
RPC-2.92 jack
RTK 106
02S121-2U1S3
02K121-2U1S3
Electrical data
Impedance
Frequency
Return loss1
Insertion loss1
50 Ω
DC to 40 GHz
≥ 17 dB, DC to 40 GHz
see table available variants
Individual testing and documentation:
Measurement plot with all 4 S-Parameters (S11; S22; S21; S12) is included with the cable assembly and on
the backside the care and handling instruction is printed. Measurement adaptors used are mentioned in the
commentary field.
1 Return Loss and Insertion Loss includes the measurement adaptor
Mechanical data
Minimum bend radius:
Single
Multiple
6.35 mm
38.4 mm
Environmental data
Temperature range
RoHS
-40°C to +85°C
compliant
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Martin Moder
Date
02/07/15
Approved
Herbert Babinger
Date
07/07/15
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Rev. Engineering change number
m00
15-s277
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Name
Kathrina Mitterer
Date
07/07/15
Page
1/1