English
Language : 

08CK020-150 Datasheet, PDF (1/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Kit
Technical Data Sheet
RPC-1.85
Calibration Kit
LRL Version
08CK020-150
Contents
Device
Part number
13 mm Air line plug/jack
08S101-K013
14.9 mm Air line plug/jack 08S101-K014
22.6 mm Air line plug/jack 08S101-K022
Short circuit plug
08S12S-000S3
Short circuit jack
08K12S-000S3
Combi wrench
03W008-000
Torque wrench
03W021-000
a. See “Declaration of calibration options” for explanation.
Remarks
L1
L2
L3
Reflect standard
Reflect standard
-
-
QTY
1
1
1
1
1
1
1
Calibration
Optiona
FC
FC
FC
FC
FC
FC
LRL calibrations without lowband loads are band limited. There are many different possibilities to calibrate
a VNA depending from the line length and the number of lines used during the calibration procedure. If
two lines are used the third line can be used as verification standard. The following graphs show two
possibilities using LRL with lowband loads. Without lowband loads the lower band cannot be calibrated.
Frequency Range (2 Bands)
Lowband loads
0
13
L1 and L2
70
f in GHz
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Frequency Range (3 Bands)
Lowband loads L1 and L3 L1 and L2
0
2.6
13
70
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
f in GHz
Page