English
Language : 

05CK020-150 Datasheet, PDF (1/3 Pages) Rosenberger Hochfrequenztechnik GmbH & Co. KG – Calibration Kit
Technical Data Sheet
RPC-N Calibration Kit
50 Ω LRL Version
05CK020-150
Contents
Device
Part number
26.4 mm Air line plug/jack 05S101-K026
33.3 mm Air line plug/jack 05S101-K033
61 mm Air line plug/jack
05S101-K061
Short circuit plug
05S12S-000S3
Short circuit jack
05K12S-000S3
Combi wrench
53W011-000
Torque wrench
53W009-000
a. See “Declaration of calibration options” for explanation.
Remarks
L1
L2
L3
Reflect standard
Reflect standard
-
-
QTY
1
1
1
1
1
1
1
Calibration
Optiona
FC
FC
FC
FC
FC
-
FC
LRL calibrations without lowband loads are band limited. There are many different possibilities to calibrate
a VNA depending from the line length and the number of lines used during the calibration procedure. If
two lines are used the third line can be used as verification standard. The following graphs show two
possibilities using LRL with lowband loads. Without lowband loads the lower band cannot be calibrated.
Frequency Range (2 Bands)
Lowband loads
0
3.6
L1 and L2
18
f in GHz
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Frequency Range (3 Bands)
Lowband loads L1 and L3 L1 and L2
0
0.7
3.6
18
Tel. : +49 8684 18-0
Fax : +49 8684 18-499
Email : info@rosenberger.de
f in GHz
Page
1/3