English
Language : 

BU9795AKV Datasheet, PDF (8/16 Pages) Rohm – Standard function Segment Drivers
BU9795AKV, BU9795AFV, BU9795AGUW
○ Display control (DISCTL)
MSB
LSB
D7 D6 D5 D4 D3 D2 D1 D0
C
0
1 P4 P3 P2 P1 P0
Set Frame frequency
Setting
80Hz
71Hz
64Hz
53Hz
P4
P3
0
0
0
1
1
0
1
1
Reset initialize condition
○
Set LCD drive waveform
Setting
P2
Line inversion
0
Frame inversion
1
Reset initialize condition
○
Set Power save mode
Setting
P1 P0
Reset initialize condition
Power save mode 1
0
0
Power save mode 2
0
1
Normal mode
1
0
○
High power mode
1
1
* VDD-VLCD>=3.0V is required for High power mode.
○ Set IC Operation (ICSET)
MSB
LSB
D7 D6 D5 D4 D3 D2 D1 D0
C
1
1
0
1 P2 P1 P0
P2: MSB data of DDRAM address. Please refer to “ADSET” command.
Setting
Address MSB‘0’
Address MSB‘1’
P2
Reset initialize condition
0
○
1
Set Software Reset condition
Setting
P1
No operation
0
Software Reset
1
Switch between internal clock and external clock.
Setting
P0
Reset initialize condition
Internal clock
0
○
External clock input
1
Technical Note
www.rohm.com
© 2009 ROHM Co., Ltd. All rights reserved.
8/15