English
Language : 

BU520XX_BD7411G_REVF Datasheet, PDF (7/32 Pages) Rohm – Omnipolar detection, Micro power operation (small current using intermittent operation method)(BD7411G is excluded.)
BU52001GUL,BU52011HFV,BU52021HFV,BU52015GUL,BU52025G,BU52051NVX,
BU52053NVX,BU52054GWZ,BU52055GWZ,BU52056NVX,BU52061NVX,BD7411G
Technical Note
BU52061NVX (Unless otherwise specified, VDD=1.80V, Ta=25℃)
Parameter
Limits
Symbol
Unit
Min. Typ. Max.
Power Supply Voltage
VDD
1.65 1.80 3.60 V
Operate Point
Release Point
Hysteresis
BopS
BopN
BrpS
BrpN
BhysS
BhysN
2.3
3.3
4.7
mT
-4.7 -3.3 -2.3
1.2
2.4
3.4
mT
-3.4 -2.4 -1.2
-
0.9
-
mT
-
0.9
-
Period
Tp
-
50
100 ms
Conditions
Output High Voltage
Output Low Voltage
VOH
VDD-0.2
-
-
V
BrpN<B<BrpS
IOUT =-0.5mA
※21
VOL
-
-
0.2
V
B<BopN, BopS<B
IOUT =+0.5mA
※21
Supply Current 1
IDD1(AVG)
-
4
7
µA VDD=1.8V, Average
Supply Current During Startup Time 1 IDD1(EN)
-
5.0
-
mA
VDD=1.8V,
During Startup Time Value
Supply Current During Standby Time 1 IDD1(DIS)
-
1.8
-
µA
VDD=1.8V,
During Standby Time Value
Supply Current 2
IDD2(AVG)
-
9
16 µA VDD=3.0V, Average
Supply Current During Startup Time 2 IDD2(EN)
-
9.0
-
mA
VDD=3.0V,
During Startup Time Value
Supply Current During Standby Time 2 IDD2(DIS)
-
4.4
-
µA
VDD=3.0V,
During Standby Time Value
※21 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
7/31
2010.12 - Rev.F