English
Language : 

BD71815AGW Datasheet, PDF (68/107 Pages) Rohm – System PMIC for Battery Powered Systems
BD71815AGW
Address 57h: ALM_VBAT_TH_U Register (R/W)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
ALM_VBAT_TH_U
R/W
-
-
-
-
-
-
-
VBAT_TH[12]
57h
Initial Value
01h
0
0
0
0
0
0
0
1
Address 58h: ALM_VBAT_TH_L Register (R/W)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
ALM_VBAT_TH_L
R/W
VBAT_TH[11:4]
58h
Initial Value
FFh
1
1
1
1
1
1
1
1
VBAT_TH[12:0]
Battery Voltage Alarm Threshold.
Setting Range is from 0.000V to 8.176V, 16mV steps. It will be compared with VM_VBAT[12:4] (concatenated VM_VBAT_U[12:8] and VM_VBAT_L[7:4]).
See also VBAT_MON_DET/RES alarm.
Address 59h: ALM_DCIN_TH Register (R/W)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
ALM_DCIN_TH
R/W
DCIN_TH[11:4]
59h
Initial Value
0Fh
0
0
0
0
1
1
1
1
DCIN_TH[11:4]
DCIN Voltage Alarm Threshold.
Setting Range is from 0.0V to 20.4V, 80mV steps. It will be compared with VM_DCIN[11:4] (concatenated VM_DCIN_U[11:8] and VM_DCIN_L[7:4]).
Address 5Ah: ALM_VSYS_TH Register (R/W)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
ALM_VSYS_TH
R/W
VSYS_TH[12:5]
5Ah
Initial Value
FFh
1
1
1
1
1
1
1
1
Bit 7-0 : VSYS_TH[12:5]
VSYS Voltage Alarm Threshold.
Setting Range is from 0.00V to 8.16V, 32mV steps.
Address 5Bh: VM_IBAT_U Register (R)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
VM_IBAT_U
R
IBAT_DIR
-
-
-
IBAT[11:8]
5Bh
Initial Value
00h
0
0
0
0
0
0
0
0
Address 5Ch: VM_IBAT_L Register (R)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
VM_IBAT_L
R
IBAT[7:0]
5Ch
Initial Value
00h
0
0
0
0
0
0
0
0
Measured Battery Current
IBAT_DIR
0 : Charging
1 : Discharging
Current Direction
IBAT[11:0]
Absolute Current , 0.000A to 4.095A range(0.00A to 4.063A clamp), 1mA steps (RSENS=10mohm).
Absolute Current , 0.000A to 1.365A range(0.00A to 4.063A clamp), 0.33mA steps (RSENS=30mohm).
Series of IBAT_DIR and IBAT[11:0] (address from 5Bh to 5Ch) should be read in accordance with continuous manner,
so stop condition should not be inserted during reading these registers.
Address 5Dh: VM_VBAT_U Register (R)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
VM_VBAT_U
R
-
-
-
VBAT[12:8]
5Dh
Initial Value
00h
0
0
0
0
0
0
0
0
Address 5Eh: VM_VBAT_L Register (R)
Address
(Index)
Register Name
R/W
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
VM_VBAT_L
R
VBAT[7:0]
5Eh
Initial Value
00h
0
0
0
0
0
0
0
0
VBAT[12:0]
Measured Battery Voltage. 0.000V to 8.191V range(0.4V to 5.6V clamp), 1mV steps.
This register value is also used for Over-Voltage detection and some Charger functions.
Series of VBAT[12:0] (address from 5Dh to 5Eh) should be read in accordance with continuous manner,
so stop condition should not be inserted during reading these registers.
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
68/103
TSZ02201-0Q4Q0AB00610-1-2
5.Oct.2016 Rev.001