English
Language : 

BU52001GUL_11 Datasheet, PDF (5/32 Pages) Rohm – Omnipolar Detection Hall ICs Line up of supply voltage
BU52001GUL,BU52011HFV,BU52021HFV,BU52015GUL,BU52025G,BU52053NVX,
BU52054GWZ,BU52055GWZ,BU52056NVX,BU52061NVX,BD7411G
Technical Note
BU52015GUL (Unless otherwise specified, VDD=1.80V, Ta=25℃)
Parameter
Limits
Symbol
Unit
Min. Typ. Max.
Conditions
Power Supply Voltage
VDD
1.65 1.80 3.30 V
Operate Point
Release Point
Hysteresis
BopS
BopN
BrpS
BrpN
BhysS
BhysN
-
3.0
5.0
mT
-5.0 -3.0
-
0.6
2.1
-
mT
-
-2.1 -0.6
-
0.9
-
mT
-
0.9
-
Period
Output High Voltage
Output Low Voltage
Tp
-
50
VOH
VDD-0.2
-
VOL
-
-
100 ms
OUT1: BrpN<B<BrpS
※19
-
V OUT2: B<BopN, BopS<B
IOUT = -0.5mA
OUT1: B<BopN, BopS<B ※19
0.2
V OUT2: BrpN<B<BrpS
IOUT = +0.5mA
Supply Current 1
IDD1(AVG)
-
5
8
µA VDD=1.8V, Average
Supply Current During Startup Time 1 IDD1(EN)
-
2.8
-
mA
VDD=1.8V,
During Startup Time Value
Supply Current During Standby Time 1 IDD1(DIS)
-
1.8
-
µA
VDD=1.8V,
During Standby Time Value
Supply Current 2
IDD2(AVG)
-
8
12 µA VDD=2.7V, Average
Supply Current During Startup Time 2 IDD2(EN)
-
4.5
-
mA
VDD=2.7V,
During Startup Time Value
Supply Current During Standby Time 2 IDD2(DIS)
-
4.0
-
µA
VDD=2.7V,
During Standby Time Value
※19 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
© 2011 ROHM Co., Ltd. All rights reserved.
5/31
2011.12 - Rev.G