English
Language : 

RGCL80TK60D Datasheet, PDF (4/13 Pages) Rohm – 600V 40A Field Stop Trench IGBT
RGCL80TK60D
Data Sheet
lFRD Electrical Characteristics (at Tj = 25°C unless otherwise specified)
Parameter
Symbol
Conditions
Values
Unit
Min. Typ. Max.
IF = 20A
Diode Forward Voltage
VF Tj = 25°C
-
1.45 1.9
V
Tj = 175°C
-
1.25
-
Diode Reverse Recovery Time
trr
-
58
-
ns
Diode Peak Reverse Recovery
Current
Diode Reverse Recovery
Charge
IF = 20A
Irr
VCC = 400V
diF/dt = 200A/μs
Qrr
Tj = 25°C
-
6.3
-
A
-
0.20
-
μC
Diode Reverse Recovery Energy Err
-
7.4
-
μJ
Diode Reverse Recovery Time
trr
Diode Peak Reverse Recovery
Current
Diode Reverse Recovery
Charge
IF = 20A
Irr
VCC = 400V
diF/dt = 200A/μs
Qrr
Tj = 175°C
Diode Reverse Recovery Energy Err
-
256
-
ns
-
10.4
-
A
-
1.35
-
μC
- 146.5 -
μJ
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
4/11