Electrical Characteristics
(VDD=3.3V, Ta=25°C, Crystal frequency 36.8640MHz, unless otherwise specified.)
Parameter
Symbol
Min
Typ
Max
Unit
Conditions
Output L Voltage
VOL
-
-
0.4
V IOL=4.0mA
Output H Voltage
VOH
2.4
-
-
V IOH=-4.0mA
Consumption Current
IDD
-
30
50
mA At no load
CLK54M
CLK54M
-
54.0000
-
MHz XTAL x 375 / 64 / 4
CLK27M
CLK27M
-
27.0000
-
MHz XTAL x 375 / 64 / 8
CLK33M
CLK33M
-
33.8688
-
MHz XTAL x 147 / 40 / 4
CLK16M
CLK768FS1
CLK384FS2
Duty
CLK16M
-
CLK768_H
-
CLK768_L
-
CLK384_H
-
CLK384_L
-
Duty
45
16.9344
36.8640
33.8688
18.4320
16.9344
50
-
MHz XTAL x 147 / 40 / 8
-
MHz
At FSEL=OPEN,
XTAL output
-
MHz
At FSEL=L,
XTAL x 147 / 40 / 4
-
At FSEL=OPEN,
MHz XTAL / 2 output
-
MHz
At FSEL=L,
XTAL x 147 / 40 / 8
55
%
Measured at a voltage of 1/2 VDD
Period-Jitter 1σ
P-J 1σ
-
50
-
psec (Note 1)
Period-Jitter
MIN-MAX
P-J
-
300
-
psec (Note 2)
MIN-MAX
Rise Time
tR
-
2.5
Fall Time
tF
-
2.5
Output Lock-Time
tLOCK
-
-
C/N 54M
C/N 54M
-65
-80
Period of transition time required for
-
nsec the clock output to reach 80% from
20% of VDD
Period of transition time required for
-
nsec the clock output to reach 20% from
80% of VDD
1
msec (Note 3)
-
dB (Note 4) (At a maximum load)
C/N 33M
C/N 33M
-50
-60
-
dB (Note 4) (At a maximum load)
(Note) The output frequency is determined by the arithmetic (frequency division) expression of a frequency input to XTALIN.
If the input frequency is set to 36.8640MHz, the output frequency will be as listed above.
(Note 1) Period-Jitter 1σ
This parameter represents standard deviation (1 ) on cycle distribution data at the time when the output clock cycles are sampled 1000 times
consecutively with the TDS7104 Digital Phosphor Oscilloscope of Tektronix Japan, Ltd.
(Note 2) Period-Jitter MIN-MAX
This parameter represents a maximum distribution width on cycle distribution data at the time when the output clock cycles are sampled 1000 times
consecutively with the TDS7104 Digital Phosphor Oscilloscope of Tektronix Japan, Ltd.
(Note 3) Output Lock-Time
The Lock-Time represents elapsed time after power supply turns ON to reach a 3.0V voltage, after the system is switched from Power-Down state to
normal operation state, or after the output frequency is switched, until it is stabilized at a specified frequency, respectively.
(Note 4) Make measurements with settings of SPAN to 100kHz, RBW to 1kHz, and VBW to 100Hz taking the middle point between (54.0000MHz±20kHz) and
(33.8688MHz±20kHz) as a measurement point.