Switching characteristics (unless otherwise noted, Ta = 25°C, VSS = 0V, CL = 50pF)
Parameter
Symbol Min. Typ. Max. Unit
VDD (V)
—
180
—
5
Output rise time
tTLH
—
90
—
ns
10
—
65
—
15
—
100
—
5
Output fall time
tTHL
—
50
—
ns
10
—
40
—
15
—
90
—
5
“L” to “H”
Propagation delay time
tPLH
—
50
—
ns
10
—
40
—
15
—
65
—
5
“H” to “L”
Propagation delay time
tPHL
—
40
—
ns
10
—
30
—
15
Input capacitance
CIN
—
5
—
pF
—
Conditions
—
—
—
—
—
Measurement
circuit
Fig.2
Fig.2
Fig.2
Fig.2
—
•Measurement circuits
VDD
A
V
P.G.
GND
Fig. 1 DC characteristics
VDD
20ns
20ns
Input
CL
tPHL
tPLH
GND
Output
VDD
VSS
VOH
VOL
tTHL
tTLH
Fig. 2 Switching characteristics