English
Language : 

EME05 Datasheet, PDF (2/4 Pages) XP Power Limited – AC-DC Power Supplies
EME05 Series
AC-DC Power Supplies
Input
Characteristic
Input Voltage Range
Input Frequency
Input Current - Full Load
No Load Input Power
Inrush Current
Earth Leakage Current
Input Protection
Minimum
85
47
Typical
0.10/0.06
Maximum
264
63
0.3
40
Internal T1.0 A/250 VAC fuse fitted in line and neutral
Units
VAC
Hz
A rms
W
A
Notes & Conditions
At 115/230 VAC
At 230 VAC
Class II construction no earth
Output
Characteristic
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature Coefficient
Minimum
3.3
0
12
115
130
Typical
Maximum
48
±1
2
14
±0.5
±1
4
50
90
120
200
140
200
0.05
Units
VDC
%
A
s
ms
ms
%
%
%
mV pk-pk
mV pk-pk
mV pk-pk
mV pk-pk
% Vnom
%
%/˚C
Notes & Conditions
No minimum load required
at full load and 115 VAC
Deviation, recovery within 1% in less than 500 µs
for a 25% load change
3.3-5 V versions, 20 MHz bandwidth
9 V versions, 20 MHz bandwidth
12-15 V versions, 20 MHz bandwidth
24-48 V versions, 20 MHz bandwidth
Recycle input to reset
Trip & Restart (hiccup mode)
General
Characteristic
Efficiency
Isolation: Input to Output
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
4000
Typical
80
130
>400
0.03 (14)
0.053 (24)
Maximum
5.5
Units
%
VAC
kHz
W/in3
kHrs
lb (g)
lb (g
Notes & Conditions
2 MOPP
MIL-HDBK-217F, +25 °C GB
Open frame versions (-P)
Encapsulated version
Efficiency Graphs
EME05US12
100%
90%
80%
70%
60%
50%
40%
10
20
30
40
50
60
70
80
90
100
Load (%)
EME05US24
100%
90%
80%
70%
60%
115Vac input
230Vac input
50%
40%
10
20
30
40
50
60
70
80
90
100
Load (%)
www.xppower.com
2