English
Language : 

BU52002GUL_1008 Datasheet, PDF (2/20 Pages) Rohm – Unipolar Detection Hall ICs
BU52002GUL,BU52003GUL,BU52012NVX,BU52012HFV,BU52013HFV
Technical Note
●Absolute maximum ratings
BU52002GUL,BU52003GUL (Ta=25℃)
Parameter
Symbol
Ratings Unit
Power Supply Voltage
VDD
-0.1~+4.5※1 V
BU52012NVX (Ta=25℃)
Parameter
Symbol
Power Supply Voltage
VDD
Ratings Unit
-0.1~+4.5※3 V
Output Current
IOUT
±1
mA
Power Dissipation
Pd
420※2
mW
Operating
Temperature Range
Topr
-40~+85 ℃
Storage
Temperature Range
Tstg
-40~+125 ℃
※1. Not to exceed Pd
※2. Reduced by 4.20mW for each increase in Ta of 1℃ over 25℃
(mounted on 50mm×58mm Glass-epoxy PCB)
Output Current
IOUT
±0.5
mA
Power Dissipation
Pd
2049 ※4
mW
Operating
Temperature Range
Topr
-40~+85 ℃
Storage
Temperature Range
Tstg
-40~+125 ℃
※3. Not to exceed Pd
※4. Reduced by 5.36mW for each increase in Ta of 1℃ over 25℃
(mounted on 70mm×70mm×1.6mm Glass-epoxy PCB)
BU52012HFV,BU52013HFV (Ta=25℃)
Parameter
Symbol
Ratings Unit
Power Supply Voltage
VDD
-0.1~+4.5※5 V
Output Current
IOUT
±0.5
mA
Power Dissipation
Pd
536※6
mW
Operating
Temperature Range
Topr
-40~+85 ℃
Storage
Temperature Range
Tstg
-40~+125 ℃
※5. Not to exceed Pd
※6. Reduced by 5.36mW for each increase in Ta of 1℃ over 25℃
(mounted on 70mm×70mm×1.6mm Glass-epoxy PCB)
●Magnetic, Electrical characteristics
BU52002GUL (Unless otherwise specified, VDD=3.0V, Ta=25℃)
Parameter
Symbol
Min.
Limits
Typ.
Max.
Unit
Power Supply Voltage
VDD
2.4
3.0
3.3
V
Conditions
Operate Point
BopS
-
3.7
5.5
mT
Release Point
BrpS
0.8
2.9
-
mT
Hysteresis
BhysS
-
0.8
-
mT
Period
Output High Voltage
Output Low Voltage
TP
-
50
100
ms
VOH
VDD-0.4
-
-
V
B<BrpS
IOUT=-1.0mA
※7
VOL
-
-
0.4
V
BopS<B
IOUT =+1.0mA
※7
Supply Current
IDD(AVG)
-
6.5
9
µA Average
Supply Current
During Startup Time
IDD(EN)
-
4.7
-
mA During Startup Time Value
Supply Current
During Standby Time
IDD(DIS)
-
3.8
-
µA During Standby Time Value
※7. B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
2/19
2010.08 - Rev.C