BDE0600G Datasheet, PDF (2/9 Pages) Rohm – Thermostat Output Temperature ICs with Variable Detection Temperature | |||
|
◁ |
BDEâ¡â¡â¡0G Series
Technical Note
âAbsolute Maximum Ratings ( Ta = 25â )
Parameters
Symbol
Limit
Unit
Power Supply Voltage
VDD
-0.3 to 7.0*1
V
Input Voltage ( CTRL )
VIN
-0.3 to VDD+0.3
V
Input Current ( CTRL )
IIN
-1.0, +0.1
mA
OS terminal Voltage
VOS
-0.3 to 7.0
V
OS terminal Current
Power dissipation
IOS
5.0
mA
Pd
540*2
mW
Storage Temperature Range
Tstg
-55 to 150
â
*1. Not to exceed Pd
*2. Reduced by 5.40mW for each increase in Ta of 1â over 25â( mounted on 70mmÃ70mmÃ1.6mm Glass-epoxy PCB )
âRecommended Operating Condition
Parameters
Symbol Min. Typ. Max. Unit
Power Supply Voltage
Operating Temperature Range
VDD
2.9
3.0
5.5
V
Topr
-30
-
130
â
âTemperature Accuracy ( Unless otherwise specified, VDD = 3.0V )
Parameters
Symbol
Min.
Limit
Typ.
Thermostat ( Temperature Switch )
Detection TemperatureAccuracy
Tacc
-
0
Detection Temperature Hysteresis Thys
7.5
10.0
Analog Output
VTemp Temperature Accuracy
TTemp
-
-
Max.
±4.0
12.5
±3.5
Unit
Conditions
â Ta = -20âï½115â
â
â Ta = 30â
âElectrical Characteristics ( Unless otherwise specified, VDD = 3.0V, Ta = 25â )
Parameter
Limits
Symbol
Min. Typ. Max.
Supply Current
IDD
-
16.0 20.0
Analog Output
VTemp Output Voltage
VTemp 1.716 1.753 1.790
Unit
Conditions
µA CTRL = 3.0V
V Ta = 30â
VTemp Temperature Sensitivity
VSE -10.28 -10.68 -11.08 mV/â Ta = -30 to 100â
VTemp Load Regulation
OS Output Open Drain
OS Leakage Current
â¿VTempRL -
IL
-
-
1
mV difference of IOUT : 0µA / 2µA
-
1.0
µA OS : 5.0V
OS Output Voltage
CTRL
Input L Voltage
VOL
-
-
VIL
GND
-
0.4
V IinOS = 1.2mA
0.6
V
Input H Voltage
*Radiation hardiness is not designed.
VIH
2.4
-
VDD
V
www.rohm.com
2/8
© 2011 ROHM Co., Ltd. All rights reserved.
2011.07 - Rev.C
|
▷ |