|
BD37524FS_1003 Datasheet, PDF (19/26 Pages) Rohm – Sound Processor with Built-in 3-band Equalizer | |||
|
◁ |
BD37524FS
Technical Note
About Level meter
ï¼ï¼ï¼ The operation of circuit
Level meter is a function which gives DC voltage proportional to the size of signal of sound. It detects
the peak level of signal and keeps the peak level, so that it is possible to monitor the size of signal by
resetting DC voltage kept with suitable interval.
ï¼ï¼ï¼ The way to reset level meter output
Please send reset data through I2C BUS
When reset output of level meterï¼Send D6 = â 1 â of select address 02(hex).
When cancel of output reset of level meter (HOLD)⦠â Send D6 = â 0 â of select address 02(hex).
ï¼ï¼ï¼ The settings about period of reset
Peak hold operation will start after HOLD data is transmitted. Set the WAIT time after HOLD data
according to the frequency bandwidth detected.
WAIT time must be set to a minimum of one cycle over the detected frequency bandwidth.
Ex) Detected frequency bandwidth is above 40Hz, ã40Hz = 25ms = WAIT timeã
transmission
Transmission Example by I2C BUS
I2CBUS
(RESET)
(HOLD)
80 1 02 40 80 02 00
0
LOUT [ V ]
RESET
START
HOLD
START
Wait time
(25msec)
â»finï¼40Hz
detect
t
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
19/25
2010.03 - Rev.A
|
▷ |