BD62210AEFV
(2) PWM Constant Current Control
Sets the current limit value.
Input range: 0V to 2V
Refer to page 5 for detail.
3.3V or 5.0V
3.3V or 5.0V
4.7kΩ
4.7kΩ
4.7kΩ
1.2kΩ
82kΩ 470pF
VREF1
11 +
-
VREF2
12 +
-
1/8 +
-
RNF1S
1/8 +
-
RNF2S
Blank time
PWM control
CR 10
OSC
Sets the switching frequency.
Setting range is
C:330pF to 680pF
R:10kΩ to 150kΩ
Refer to page 5, 8 for detail.
Control logic input terminal.
Refer to page 4.
Power save terminal
Refer to page 4 for detail.
IN1A 16
IN1B 17
IN2A 19
IN2B 20
PS 13
TEST2 18
14
TEST1
Forward
Reverse
Brake
Open
Forward
Reverse
Brake
Open
Regulator
3.3V or 5.0V
FAILA
15
10kΩ
TSD
UVLO
OCP
OVLO
7 VCC1
OUT1A
5
2 OUT1B
3
RNF1
4
RNF1S
22 VCC2
24 OUT2A
27
OUT2B
26
RNF2
25
RNF2S
1,9 GND
M
0.2Ω
M
0.2Ω
Terminal for testing
Connect to GND.
Figure 12. Application Circuit Diagram of
Constant Voltage Control or External PWM Control
When using the fault output function
⇒Pull up resistor 5kΩ to 100kΩ.
When not using the fault output
function
⇒Connect to GND.
Refer to page 5.
Bypass capacitor.
Setting range is
100µF to 470µF(electrolytic)
0.01uF to 0.1µF(multilayer ceramic
etc.)
Refer to page 4 for detail.
Be sure to short VCC1 & VCC2.
100µF
0.1µF
Current detection setting
resistor.
0.1Ω to 0.3Ω
Refer to page 4, 5 for detail.
Current detection setting
resistor
0.1Ω to 0.3Ω
Refer to page 4, 5 for detail.
(a) Input/Output table
Input
PS
IN1A
IN2A
L
X
H
L
H
H
H
L
H
H
X: H or L
IN1B
IN2B
X
L
L
H
H
Output
OUT1A
OUT2A
OUT1B
OUT2B
OPEN
OPEN
OPEN
OPEN
H
L
L
H
L
L
State
POWER SAVE (STANDBY)
STOP
FORWARD
REVERSE
BRAKE
www.rohm.com
© 2016 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
14/21
TSZ02201-0P2P0B301470-1-2
21.Jun.2016 Rev.001