English
Language : 

BD37034FV-M Datasheet, PDF (14/47 Pages) Rohm – General-Purpose Electronic Volume with Built-in Advanced Switch
BD37034FV-M
Datasheet
Select address 01(hex)
Default:8’ha4
Function Name
Mode
MSB
Initial Setup
LSB
D7
D6
D5
D4
D3
D2
D1
D0
0.6msec
0
0
Advanced Switch
1.0msec
0
1
Time of Mute
1.4msec
1
0
3.2msec
1
1
Hi-voltage
OFF
0
ON/OFF
ON
1
Level Shift
0dB
+3dB
0
1
Advanced Switch
4.7msec
0
0
Time of
7.2msec
0
1
Volume /Fader
11.2msec
1
0
/Tone/Loudness
14.4msec
1
1
Anti Alias Filter
OFF
0
ON/OFF
ON
1
Advanced Switch
OFF
0
ON/OFF
ON
1
Select address 02(hex)
Default:8’h00
Function Name
Mode
MSB
LPF Setup
LSB
D7
D6
D5
D4
D3
D2
D1
D0
55Hz
0
0
0
85Hz
0
0
1
120Hz
0
1
0
Subwoofer
160Hz
0
1
1
LPF fc
PASS
1
0
0
1
0
1
Prohibition
1
1
0
1
1
1
Subwoofer
Loudness
0
Input Selector1 Input Selector
1
Subwoofer
1ch(S1/S1)
0
0
Subwoofer
Front(F1/F2)
0
1
Output Selector Rear(R1/R2)
1
0
Subwoofer(S1/
S2)
1
1
Level Meter
Hold
0
Reset (*1)
Reset
1
LPF Phase
0°
0
0°/180° (*2)
180°
1
: Initial condition
(*1): If “Level Meter Reset” is set as Reset(“b1), a reset pulse will be outputted only once to a level meter block.
Also about this register, after a reset pulse output returns to a Hold(“b0) state, without holding a Reset(“b1) state.
Therefore, in order to change into a Hold state, it is not necessary to carry out a register setup again.
(*2): If Subwoofer LPF fc is set as 「PASS」('b000), LPF PHASE is compulsorily fixed to 0°('b0).
www.rohm.com
© 2013 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
14/44
TSZ02201-0C2C0E100010-1-2
4.OCT.2013 Rev.002