English
Language : 

BP5716_10 Datasheet, PDF (1/4 Pages) Rohm – Isolated AC/DC Converter
Data Sheet
100VAC Input/12VDC (1A) Output
Isolated AC/DC Converter
BP5716
Absolute Maximum Ratings
Parameter
Symbol Limits Unit
Conditions
8-pin input voltage
VD
6-pin input voltage
VDD
8-pin input current
ID
6-pin input current
IDD
Maximum Power
Po
Withstanding voltage
Vi
Allowable maximum surface temperature Tcmax
Operating temperature range Topr
Storage temperature range Tstg
500
25
500
10
13
2.5
105
−25 to +80
−40 to +105
V
V
mA
mA
W
kV 1s (primary-secondary)
°C Ambient temperature + The module self-heating Tcmax
°C
°C
Electrical Characteristics
<Input conditions>
(Unless otherwise noted, Vi=141V, Ta=25°C)
Parameter
Symbol Min. Typ. Max. Unit
Conditions
8-pin input voltage VD
− − 350 V Io=1000mA
Operating power voltage VDD 8.8 12 20 V DC, Io=1000mA
∗1
<12V output>
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Output voltage
Output current
Line regulation
Vo 11.4 12.0 12.6 V
Io
0
− 1000 mA Refer to derating curve
Vr
− 10 200 mV Vi=113V to 170VDC, Io=1000mA
Load regulation
VI
− 58 200 mV Io=50mA to 1000mA
Output ripple voltage Vp
− 300 500 mVpp
∗2
Power conversion efficiency η
75 84 − %
∗1 Operating start voltage is15.5V to 17.5V. ∗2 Pulse noise not included.
Application Circuit
AC100V
ZNR D7
F1
Vi(+)
R5
R1
C4 C7
Vi(-)
68
Be sure to use fuse
for safety.
5
T1 D1
3
9
C2
C1
D2 1
10
D3
4
C3 5
D5
6
7 C6
C5
2
BP5716
Vo:12V/850mA
GND1
Vo:18V/100mA
GND2
1
Pin No.
1
Name
Vo
Function
This is the secondary side 12V output voltage
control terminal. Insert the output smoothing
capacitor 1000µF between GND.
2
GND
This is the GND terminal for the secondary
side 12V output.
5
Vi(-) This is the primary side input minus terminal.
6
VDD This is the internal circuit power supply terminal.
This is the built-in FET of drain terminal. The primary coil
8
VD minus side of the external transformer, and the snubber
circuit for noise reduction are connected to this.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
C1: Output smoothing capacitor
C2: Noise reduction capacitor
C3: Output smoothing capacitor
C4: Input smoothing capacitor
C5: Noise reduction capacitor
C6: Output smoothing capacitor
C7: Noise terminal voltage
countermeasure capacitor
D1: Rectifier diode
D2: Rectifier diode
D3: Rectifier diode
D5: Rectifier diode
D7: Diode bridge
R1: Resistor
R5: Noise reduction resistor
T1: Switching transformer
F1: Fuse
ZNR: Varistor
1000µF / 35V, low impedance
2200pF / 400V or higher
10µF / 50V, low impedance
33µF / 250V
Use if necessary
100µF / 35V, low impedance
Use if necessary
Limiting element voltage 250V or higher, 0.1 to 0.22µF
60V / 6A
1kV / 1A
80V / 0.1A
100V or higher / 1A
800V / 1A
100kΩ ± 5% 3W Limiting element voltage 300V or higher
Use if necessary
1W or higher 10 to 22Ω
Be sure to use this for safety
A varistor is required to protect against lightning surges and
static electricity.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1
Dimensions (Unit : mm)
24.0Max.
10.1Max.
MARKING SIDE
2.54x7=17.78TYP.
4.55MAX.
5.55MAX.
Derating Curve
Derating Curve
12
Operation Range
6
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta (°C)
Switching Frequency
Switching Frequency
(Vi=141V)
100
80
60
40
20
0
0 200 400 600 800 1000
Output Current Io (mA)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Vi=141V)
200 400 600 800 1000
Output Current Io (mA)
Load Regulation
Load Regulation
14.0
(Vi=141V)
12.0
10.0
8.0
6.0
4.0
Maximum
2.0
Io=1000mA
0.0
0 200 400 600 800 1000 1200 1400 1600
Output Current Io (mA)
Surface Temperature Increase
Surface Temperature Increase
40
(Ta=25°C, Vi=141V)
30
20
10
0
0 200 400 600 800 1000
Output Current Io (mA)
2010.01 - Rev.A