English
Language : 

BP5075-12 Datasheet, PDF (1/3 Pages) Rohm – Non-isolated AC / DC Converter
AC110V input, -12V / 100mA output
Non-isolated AC / DC Converter
BP5075-12
Absolute Maximum Ratings
Dimensions (Unit : mm)
Parameter
Symbol
Limits
Unit
20.5MAX.
10.7MAX.
Input voltage
Vin
−187
V
Operating temperature range
Topr
Storage temperature range
Tstg
−20 to +80
°C
−25 to +105
°C
MARKING SIDE
Case temperature
Output current
Tsmax
105
Iopeak
100
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
°C
mApk
Conditions
1
456 7
3.25MAX.
0.5±0.1
P=2.54±0.2
1.3±0.2
2.54x6=15.24TYP.
4.45MAX.
0.25±0.05
6.25MAX.
Input voltage
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Conversion efficiency
Vin −113
Vo −11.7
Io ∗1 −
Vr
−
Vl
−
Vp ∗2 −
η
68
−141
−12.5
−
0.02
0.01
0.04
73
−187
−13.2
100
0.20
0.20
0.20
−
V
V
mA
V
V
Vp-p
%
DC
Vin=−141V, Io=50mA
Vin=−113 to −187V
Vin=−141V, Io=0 to 50mA
Vin=−141V, Io=50mA
Vin=−141V, Io=100mA
∗1Max output current should be reduced according to the surrounding temperature.
∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components. Especially right
attention has to be paid to aluminum electrolytic capacitor, because ESR changes greatly at the time of the low temperature and output ripple
voltages increase.
Derating Curve
120
100
80
60
Operation Range
40
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature Ta(°C)
Application circuit
Be sure to use fuse for safety.
BP5075-12
1
4567
D1
R1 FUSE
−
Vin
ZNR
+ C1
C3
−
C2 +
Pin No. Functions
1 Input terminal
2 Skip
3 Skip
4 COMMON
5 COMMON
6 NC
7 Output terminal
A−
V−
Vo
Conversion Efficiency
Conversion Efficiency
(Vi= −141V,Ta=25°C )
100
80
60
40
20
0
0 20 40 60 80 100 120
Output Current Io(mA)
For actual usage, Please kindly evaluate and confirm our part mounted in your product.
Especially, Please make sure to confirm whether the load current exceed absolute maximum
rating by using current probe.
External components setting
FUSE: Fuse
Please make sure to use quick acting fuse (1.0A)
Load Regulation
-14.0
Load Regulation
( Vi= −141V,Ta=25°C)
-12.0
-10.0
C1: Input capacitor
C2: Output capacitor
above 250V, 10 to 47µF
above 25V, 47 to 470µF, Low impedance
ESR:0.42Ω Max.
Ripple current 0.2Arms above
Impedance of capacitor effects the output ripple voltage.
-8.0
-6.0
-4.0
-2.0
0.0
0
Maximum
Io=100mA
20 40 60 80 100 120 140
Output Current Io(mA)
C3: For noise terminal
Above 250V, 0.1 to 0.22µF
voltage reduction capacitor Film capacitor or Ceramic capacitor
Reduce the noise terminal voltage.
The constant value should be evaluated in the product.
R1: For noise terminal
10 to 100Ω, 1/4W
voltage reduction resistor Reduce the noise terminal voltage.
The constant value should be evaluated in the product.
D1: Rectifier diode
Use a rectifying diode with the peak reverse voltage of 400V or higher,
the average rectification current of 1A or larger
and the peak surge current of 40A or larger.
When using an input capacitor of a large capacity,
choose a component that endures the inrush current on power-up.
This product is compatible with full-wave rectification.
Temperature Curve
Surface Temperature Increase
(Vi= −141V,Ta=25°C, )
60
50
40
30
20
10
00 20 40 60 80 100
Output Current Io(mA)
ZNR: Varistor
Varistor must be used.It protects this part from lightning surge and static electricity.
www.rohm.com
1/1
○c 2009 ROHM Co., Ltd. All rights reserved.
2009.08 - Rev.A