English
Language : 

BP5068A24 Datasheet, PDF (1/3 Pages) Rohm – AC100V input, -24V/600mA output
AC/DC converter
AC100V input, −24V/600mA output
BP5068A24
Absolute Maximum Ratings
Parameter
Symbol
Limits
Unit
Input voltage
Output current
Vi
−90
V
Io
0.8
Apk
ESD endurance
Vsurge
2
kV
Operating temperature range
Topr
−20 ∼ +80
°C
Storage temperature range
Tstg
−25 ∼ +105
°C
Dimension(Unit : mm)
34.5MAX.
11.3MAX.
1 3 5 7 8 10 12
3.25MAX
0 . 5 ±0 . 1
1 . 3 ±0 . 2 P=2.54±0.2
2.54×11=27.94
0 . 2 5 ±0 . 0 5
7.35MAX.
3.95MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi −162 −141 −120 V DC(85∼115VAC)
Output voltage
Vo −26 −24 −22 V Vi=−141V, Io=600mA
Output current
Io
0
−
0.6
A Vi=−141V
∗1
Line regulation
Vr
− 0.23 0.48 V Vi=−120∼ −162V, Io=600mA
Load regulation
Vl
− 0.55 0.75 V Vi=−141V, Io=0∼600mA ∗2
Output ripple voltage Vp
−
0.11 0.20 Vp-p Vi=−141V, Io=600mA
Power conversion effciency η
82
88
−
% Vi=−141V, Io=600mA ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion effciency.
Application circuit
BP5068A24
Please note that pin No.12
side is input.
12
87
D1
R1
FUSE
2A
1SR35-400A 2.2Ω1/4W
Input
AC100V
50Hz/60Hz
ZNR − C1
C2
220V + 100µF/200V 0.1µF
53
L1
D1
Pin No.
Function
1 Output terminal Vo(−24V)
2 Not used
3 Coil connect
4 Not used
5 Coil Connect
6 Not used
7 COMMON
8 COMMON
9 Not used
1
10 N.C.
11 Not used
Output 12
−24V
Input terminal Vi(−141VDC)
− C3
+ 470µF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Flywheel diode
D2: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 2A
Capacitance : 47µF∼220µF Rated voltage : 200V or higher
Ripple current is 0.22Arms above.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 330µF∼1000µF Rated voltage : 50V or higher,
ESR is 0.08Ω max. Ripple current is 1Arms above.
Output noise voltage is inflenced. Please evaluate it in the actual set.
Please use the first recovery diode that reverse peak voltage is 400V or
higher, and the avarage rectifying current is 3A or higher.That switching
characteristic and efficiency of our module is influenced by this diode
characteristic, please use 31DF4(Nihon inter), or RV30(Sanken).
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 1A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in our part.)
Coil for switching regulator. The inductance should be 330µH,
the rated direct current should be 1.3A above. Otherwise heating or
abnormal oscilation occurs.
1.0Ω∼2.2Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
Operation Range
0.2
0.1
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=−141V)
100 200 300 400 500 600
Output Current Io(mA)
Load Regulation
Load Regulation
30
(Ta=25°C, Vi=−141V)
25
20
15
10
5
0
0 100 200 300 400 500 600 700 800 900
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=−141V)
30
25
20
15
10
5
0
0 100 200 300 400 500 600
Output Current Io(mA)