English
Language : 

BP5065C Datasheet, PDF (1/3 Pages) Rohm – AC/DC converter AC100V input, −12V/90mA output
AC/DC converter
AC100V input, −12V/90mA output
BP5065C
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
−170
90
2
−20 ∼ +85
−25 ∼ +105
Unit
V
mApk
kV
°C
°C
Dimension(Unit : mm)
26.1MAX.
7.2MAX.
3.0MAX
12
4
6
9
P = 2 . 5 4 ±0 . 2
0 . 5 ±0 . 1
1 . 3 ±0 . 2
2.54×8=20.32
0 . 2 5 ±0 . 0 5
4.0MAX.
3.2MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi −113 −141 −170 V DC(80∼120VAC)
Output voltage
Vo −11 −12 −13
V Vi=−141V, Io=50mA
Output current
Line regulation
Io
0
−
90 mA Vi=−141V
∗1
Vr
− 0.05 0.15 V Vi=−113∼ −170V, Io=50mA
Load regulation
Vl
−
0.07 0.20
V Vi=−141V, Io=0∼50mA ∗2
Output ripple voltage Vp
−
0.05 0.15 Vp-p Vi=−141V, Io=50mA
Power conversion effciency η
60
68
−
% Vi=−141V, Io=90mA ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion effciency.
Application circuit
BP5065C
Please note that pin No.9
side is input.
9
6
FUSE
D1
R1
0.5A
1SR35-400A 10Ω1/4W
Input
AC100V
50Hz/60Hz
ZNR − C1
220V + 10µF/250V
C2
0.1µF
4 21
Pin No.
Function
1 Output terminal Vo(-12V)
2 Coil connect
3 Not used
4 Coil connect
5 Not used
6 COMMON
7 Not used
8 Not used
9 Input terminal Vi(-141V)
Output
−12V
L1 − C3
+ 100µF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 0.5A
Capacitance : 4.7µF∼22µF Rated voltage : 200V or higher
Ripple current is 0.13Arms above.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 100µF∼470µF Rated voltage : 25V or higher,
ESR is 0.39Ω max. Ripple current is 0.1Arms above.
Output noise voltage is influenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectufier can be used in out part.)
Coil for switching regulator. The inductance should be 1mH,
the rated direct current should be 0.18A above.
Otherwise heating or abnormal oscilation occurs.
10Ω∼22Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
100
90
80
70
60
50
40
Operation Range
30
20
10
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Switching Frequency
100
90
80
70
60
50
40
30
20
10
0
0
Switching Frequency
(Ta=25°C, Vi=−141V)
10 20 30 40 50 60 70 80 90
Output Current Io(mA)
Conversion Efficiency
Conversion Efficiency
(Ta=25°C, Vi=−141V)
80
70
60
50
40
60% Min−Line
30
20
10
0
0 10 20 30 40 50 60 70 80 90
Output Current Io(mA)
Load Regulation
13.0
12.8
12.6
12.4
12.2
12.0
11.8
11.6
11.4
11.2
11.0
0
Load Regulation
(Ta=25°C, Vi=−141V)
10 20 30 40 50 60 70 80 90
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=−141V)
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90
Output Current Io(mA)
1/2