English
Language : 

BP5062 Datasheet, PDF (1/3 Pages) Rohm – AC100V input, −12V/500mA output
AC/DC converter
AC100V input, −12V/500mA output
BP5062
Absolute Maximum Ratings
Parameter
Symbol
Limits
Unit
Input voltage
Output current
Vi
−190
V
Io
500
mA
ESD endurance
Vsurge
2
kV
Operating temperature range
Topr
−20 ∼ +80
°C
Storage temperature range
Tstg
−25 ∼ +105
°C
Dimension(Unit : mm)
34.5MAX.
9.9MAX.
3.3MAX
1 3 5 7 8 10 12
0 . 5 ±0 . 1 1 . 3 ±0 . 2
P = 5 . 0 8 ±0 . 2
2.54×11=27.94
0 . 2 5 ±0 . 0 5
5.05MAX.
4.85MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi
Output voltage
Vo
Output current
Io
Line regulation
Vr
Load regulation
Vl
Output ripple voltage Vp
Power conversion effciency η
−113
−11.0
0
−
−
−
75
−141
−12.0
−
0.05
0.07
0.05
83
−180
−13.0
500
0.15
0.20
0.15
−
V DC (80∼127VAC)
V Vi=−141V, Io=300mA
mA Vi=−141V
∗1
V Vi=−113V∼ −170V, Io=300mA
V Vi=−141V, Io=0∼300mA
Vp-p Vi=−141V, Io=300mA ∗2
% Vi=−141V, Io=500mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Application circuit
BP5062
Please note that pin No.12
side is input.
12 10
D1
R1
FUSE
2A
1SR139-400 10Ω1/4W
Input
AC100V
50Hz/60Hz
ZNR − C1
C2
220V + 47µF/200V 0.1µF
87
53
L1
470µH
Pin No.
Function
1 Output terminal Vo(−12V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 COMMON
9 Not used
1
10 N.C.
11 Not used
Output 12 Input terminal Vi(−141VDC)
−12V
− C3
+ 220µF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 2A
Capacitance : 47µF Rated voltage : 200V or higher
Ripple current is 0.22Arms above.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 220µF∼470µF Rated voltage : 25V or higher,
ESR is 0.25Ω max. Ripple current is 0.4Arms above.
Output noise voltage is infulenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 1A or higher,
and the peak surge current should be 40A or higher.
(Full-wave rectifier can be used in out part.)
Coil for switching regulator. The inductance should be 470µH,
the rated direct current should be 1.0A above.
Otherwise heating or abnormal oscilation occurs.
10Ω∼22Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
600
500
400
300
Operation Range
200
100
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=−141V)
100 200 300 400 500
Output Current Io(mA)
Load Regulation
Load Regulation
14
(Ta=25°C, Vi=−141V)
12
10
8
6
4
2
0
0 100 200 30 400 500 600 700
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=−141V)
50
40
30
20
10
0
0 100 200 300 400 500
Output Current Io(mA)
1/2