English
Language : 

BP5061 Datasheet, PDF (1/3 Pages) Rohm – AC100V input, −12V/300mA Output
AC/DC converter
AC100V input, −12V/300mA Output
BP5061
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
−170
300
2
−25 ~ +80
−25 ~ +105
Unit
V
mApk
kV
°C
°C
Dimension(Unit : mm)
35.0MAX.
9.1MAX.
3.6MAX
1357
10 1
0 . 5 ±0 . 1 1 . 3 ±0 . 2
5 . 0 8 ±0 . 2
7 . 6 2 ±0 . 3
2.54×11=27.94
0 . 2 5 ±0 . 0 5
4.85MAX.
4.25MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi −113 −141 −170 V DC (80∼120VAC)
Output voltage
Vo −11.0 −12.0 −13.0 V Vi=−141V, Io=200mA
Output current
Io
0
−
300 mA Vi=−141V
∗1
Line regulation
Vr
− 0.04 0.15 V Vi=−113V∼ −170V, Io=200mA
Load regulation
Vl
− 0.05 0.15 V Vi=−141V, Io=0∼200mA
Output ripple voltage Vp
−
0.07 0.15 Vp-p Vi=−141V, Io=200mA ∗2
Power conversion effciency η
70
78
−
% Vi=−141V, Io=300mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Application circuit
BP5061
Please note that pin No.12
side is input.
Input
AC100V
50Hz/60Hz
12
D1
1SR35−400
R1
10Ω1/4W
FUSE
1A
ZNR − C1
C2
220V + 33µF/200V 0.1µF
Pin No.
Function
1 Output terminal Vo(−12V)
2 Not used
3 Coil connect
4 Not used
5 Coil connect
6 Not used
7 COMMON
8 Not used
9 Not used
7 531
10 N.C.
11 Not used
Output 12 Input voltage Vi(−141VDC)
−12V
L1
1mH − C3
+ 100µF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
L1: Choke coil
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 1A
Capacitance : 22µF Rated voltage : 200V or higher
Ripple current is 0.13Arms above.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 100µF∼470µF Rated voltage : 25V or higher,
ECR is 0.4Ω max. Ripple current is 0.25Arms above.
Output noise voltage is infulenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in out part.)
Coil for switching regulator. The inductance should be 1mH,
the rated direct current should be 0.6A above.
Otherwise heating or abnormal oscilation occurs.
10Ω∼22Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
350
300
250
200
150
Operation Range
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=−141V)
50 100 150 200 250 300
Output Current Io(mA)
Load Regulation
Load Regulation
13.0
(Ta=25°C, Vi=−141V)
12.5
12.0
11.5
11.0
0
50 100 150 200 250 300
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=−141V)
50
45
40
35
30
25
20
15
10
5
0
0 50 100 150 200 250 300 350
Output Current Io(mA)
1/2