English
Language : 

BP5047B15 Datasheet, PDF (1/3 Pages) Rohm – AC/DC converter AC220V input, 15V/150mA output
AC/DC converter
AC220V input, 15V/150mA output
BP5047B15
Absolute Maximum Ratings
Dimensions (Unit : mm)
Parameter
Input voltage
Operating temperature range
Storage temperature range
Case temperature
Output current
Symbol
Vi1
Vi2
Topr
Tstg
TcMAX
IoMAX1
IoMAX2
Limits
430
550
−20 to +80
−25 to +105
105
150
130
Unit
Remark
V DC
V Plus 1mSMax.
°C Refer to derating curve
°C
°C
Ambient temperature+
The module self-heating Tcmax
mA PEAK value of current (Vi=180 to 390V)
mA PEAK value of current (Vi=390 to 430V) 3.25MAX.
32.5MAX.
10.1MAX.
1 35 7
0.5±0.1
P=5.08±0.2 1.3±0.2
2.54×9=22.86
10
0.25±0.05
4.55MAX.
5.55MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 180 311 430 V DC
Output voltage
Vo 14.2 15.2 16.2 V Vi=311V, Io=100mA
Output current1
Io1 0
− 150 mA Vi=180 to 390V
Output current2
lo2 0
− 130 mA Vi=390 to 430V
Line regulation
Vr −0.20 0.05 0.20 V Vi=180 to 430V, Io=100mA
Load regulation
Vl −0.20 0.05 0.20 V Vi=311V, Io=0 to 100mA
Output ripple voltage Vp
− 0.07 0.15 Vp-p Vi=311V, Io=100mA
Power conversion efficiency η
70 75
−
% Vi=311V, Io=100mA
Application circuit
BP5047B15
Be sure to use fuse for safety.
10 7 5 3 1
Ii
D1
R1
+
Vi
ZNR − C1
FUSE
C3
L1 +
−
Io
C2 Vo
Pin No.
Function
1 Output terminal: Vo(+15VDC)
2 Skip
3 Power inductor terminal
4 Skip
5 Power inductor terminal
6 Skip
7 COMMON
8 Skip
9 Skip
10 Input terminal Vi(+311VDC)
Verify proper operation under actual conditions before use. In particular, confilm that
the load current dose not exceed the maximumrating.
Derating Curve
Derating Curve
250
200
150
100
Operation Range
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=311V)
20 40 60 80 100 120 140 160
Output Current Io(mA)
Load Regulation
16.4
16.2
16.0
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
0
Load Regulation
(Ta=25°C, Vi=311V)
20 40 60 80 100 120 140 160
Output Current Io(mA)
External components setting
FUSE: Fuse
C1: Input Capacitor
C2: Output Capacitor
C3: For noise terminal
voltage reduction capacitor
L1: Power inductor
D1: Rectifier diode
R1: For noise terminal
voltage reduction resistor
ZNR: Varistor
Surface Temperature Rising
Please make sure to use quick acting fuse (1A)
above 450V, 3.3µF to 33µF
Ripple current 0.13Arms above
above 35V, 100µF to 470µF, Low impedance
ESR : 0.4Ω Max.
Ripple current 0.25Arms above
Impedance of capacitor effects the output ripple voltage.
above 450V, 0.1µF to 0.22µF
Film capacitor or Ceramic capacitor
reduce the noise terminal voltage.
The constant value should be evaluated in the product.
Surface Temperature Rising
(Ta=25°C, Vi=311V)
50
45
40
35
30
25
20
15
10
5
0
0
50
100
150
Output Current Io(mA)
Inductance : 1mH, Rating current: above 400mA
Choose components that do not easily get magnetically saturated in
high temperature.
Recommended part : C10-FR 1.0mH(MITSUMI)
Use a rectifying diode with the peak reverse voltage of 800V or higher,
the average rectification current of 1A or larger and the peak surge
current of 20A or larger. When using an input capacitor of a large capacity,
choose a component that endures the inrush current on power-up.
This products is compatible with full-wave rectification.
10Ω to 22Ω 1/4W
Reduce the noise terminal voltage.
The constant value should be evaluated in the product.
Varistor must be used. It protects this part from lightning surge and static
electricity.