AC/DC converter
AC220V input, 15V/80mA output
BP5041B15
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
390
80
2
-25 ~ +80
-25 ~ +105
Unit
V
mApk
kV
°C
°C
Dimension(Unit : mm)
32.5MAX.
11.5MAX.
3.25MAX
1
3
5
P=5.08±0.2
22.86
7
10
0.5±0.1
1.3±0.2
0.25±0.05
4.75MAX.
6.75MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi
226 282 390 V DC(160~276VAC)
Output voltage
Vo 14.0 15.0 16.0 V Vi=282V, Io=50mA
Output current
Line regulation
Io
0
-
80 mA Vi=282V
*1
Vr
- 0.05 0.15 V Vi=226~390V, Io=50mA
Load regulation
Vl
Output ripple voltage Vp
- 0.05 0.15 V Vi=282V, Io=0~50mA *2
- 0.05 0.15 Vp-p Vi=282V, Io=50mA
Power conversion effciency h
50 64
-
% Vi=282V, Io=80mA
*2
*1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
*2 Please refer to Load regulation, Conversion effciency.
Application circuit
Pin No.
Function
BP5041B15
1 Output terminal Vo(15V)
2 Not used
3 N.C.
Please note that pin No.10
4 Not used
side is input.
5 COMMON
6 Not used
7 N.C.
10
753 1
8 Not used
9 Not used
FUSE
R1
0.5A
Output 10 Input terminal Vi(282VDC)
D1
10W1/4W
+15V
Input
AC200V
50Hz/60Hz
ZNR + C1
- 4.7mF/450V
C2
0.1mF
+ C3
- 100mF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 0.5A
Capacitance : 3.3mF~22mF Rated voltage : 450V or higher
Ripple current is 0.13Arms above.
Capacitance : 0.1mF~0.22mF Rated voltage : 450V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 100mF~470mF Rated voltage : 25V or higher,
ESR is 0.39W max. Ripple current is 0.1Arms above.
Output noise voltage is influenced. Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
800V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in out part.)
10W~22W 1/4W
Reduce the noise terminal voltage. The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lightning surge and static
electricity.
Derating Curve
Derating Curve
120
100
80
60
Operation Range
40
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=282V)
10 20 30 40 50 60 70 80
Output Current Io(mA)
Load Regulation
16.0
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
14.0
0
Load Regulation
(Ta=25°C, Vi=282V)
10 20 30 40 50 60 70 80
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C,Vi=282V)
25
20
15
10
5
0
0 10 20 30 40 50 60 70 80
Output Current Io(mA)
Rev.A