English
Language : 

BP5041A5_10 Datasheet, PDF (1/4 Pages) Rohm – Non-Isolated AC/DC Converter
Data Sheet
220VAC Input/5VDC (100mA) Output
Non-Isolated AC/DC Converter
BP5041A5
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
390
100
2
−25 to +80
−25 to +105
Unit
V
mApk
kV
°C
°C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 226 282 390 V DC(160 to 276VAC)
Output voltage
Vo
4.7 5.0 5.3
V Vi=282V, Io=50mA
Output current
Io
0
− 100 mA Vi=282V
∗1
Line regulation
Vr
− 0.05 0.15 V Vi=226 to 390V, Io=50mA
Load regulation
Vl
− 0.05 0.15 V Vi=282V, Io=0 to 50mA ∗2
Output ripple voltage Vp
− 0.05 0.15 Vp-p Vi=282V, Io=50mA
Power conversion efficiency η
35 48
−
% Vi=282V, Io=100mA ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Application Circuit
Pin No.
Function
BP5041A5
Please note that pin No.10
side is input.
1 Output terminal Vo(5V)
2 Not used
3 N.C.
4 Not used
5 COMMON
6 Not used
7 N.C.
10
753 1
8 Not used
9 Not used
FUSE
R1
0.5A
Output 10 Input terminal Vi(282VDC)
D1
10Ω1/4W
+5V
Input
AC200V
50Hz/60Hz
ZNR + C1
− 4.7µF/450V
C2
0.1µF
+ C3
− 100µF/16V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: Fuse
Use a quick-acting fuse of 0.5A
C1: Input smoothing
capacitor
Capacitance : 3.3 to 22µF Rated voltage : 450V or higher
Ripple current is 0.13Arms or greater.
C2: Noise reduction
capacitor
C3: Output smoothing
capacitor
D1: Rectifier diode
Capacitance : 0.1 to 0.22µF Rated voltage : 450V or higher
Use a film or ceramic capacitor. Evaluate under actual
operating conditions.
Capacitance : 100 to 470µF Rated voltage : 16V or higher,
ESR is 0.4Ω max. Ripple current is 0.15Arms or greater.
Evaluate under actual operating conditions.
In the absolute maximum ratings, the reverse peak voltage should be
800V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used.)
R1: Noise reduction
resistor
ZNR: Varistor
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
A varistor is required to protect against lightning surges and
static electricity.
Dimensions (Unit : mm)
32.5MAX.
11.5MAX.
3.25MAX.
1
3
5
P = 5 . 0 8 ±0 . 2
22.86
7
10
0 . 5 ±0 . 1
1 . 3 ±0 . 2
0 . 2 5 ±0 . 0 5
4.75MAX.
6.75MAX.
Derating Curve
Derating Curve
120
100
80
60
Operation Range
40
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta (°C)
Conversion Efficiency
Conversion Efficiency
100
(Ta=25°C, Vi=282V)
80
60
40
20
0
0 20 40 60 80 100
Output Current Io (mA)
Load Regulation
5.3
5.2
5.1
5.0
4.9
4.8
4.7
0
Load Regulation
(Ta=25°C, Vi=282V)
20 40 60 80 100
Output Current Io (mA)
Temperature Increase
Temperature Increase
(Ta=25°C, Vi=282V)
30
25
20
15
10
5
0
0 20 40 60 80 100
Output Current Io (mA)
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1