English
Language : 

BP5039A_10 Datasheet, PDF (1/4 Pages) Rohm – Non-Isolated AC/DC Converter
Data Sheet
100VAC Input/24VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5039A
Absolute Maximum Ratings
Parameter
Input voltage
Maximum output current
ESD endurance
Maximum surface temperature
Operating Temperature range
Storage temperature range
Symbol
Vcc
IoMAX
Vsurge
TcMAX
Topr
Tstg
Limits
170
200
2
105
−20 to +80
−25 to +105
Unit
V
mApk
kV
°C
°C
°C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 113 141 170
V DC (80 to 120VAC)
Output voltage
Vo 22 24 26
V Vi=141V, Io=100mA
Output current
Io
0
− 200 mA Vi=141V
∗1
Line regulation
Vr −0.50 0.30 0.50 V Vi=113 to 170V, Io=100mA
Load regulation
Vl −0.50 0.25 0.50 V Vi=141V, Io=0 to 100mA ∗2
Output ripple voltage Vp
− 0.07 − Vp-p Vi=141V, Io=100mA
Power conversion efficiency η
70
82
−
% Vi=141V, Io=200mA ∗2
Output current at
Io1 200 245 −
mA Vi=170V, Output short, Ta=25°C
overcurrent Io2 150 220
mA Vi=170V, Output short, Ta=80°C
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Application Circuit
BP5039A
Be sure to use fuse for safety.
12 10 7 5 3 1
DC motor
Ii
D1
R1
+
Vi
ZNR − C1
FUSE
C3
Io
L1 +
− C2 Vo
Pin No.
Function
1 Output terminal Vo(24V)
2 Not used
3 Choke coil connect
4 Not used
5 Choke coil connect
6 Not used
7 COMMON
8 Not used
9 Not used
10 N.C.
11 Not used
12 Input terminal Vi(141VDC)
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: FUSE
C1: Input capacitor
C2: Output capacitor
C3: Noise reduction
capacitor
Use a quick-acting fuse of (1A)
above 250V, 22 to 820µF
Ripple current 0.13Arms or above
above 25V, 100 to 470µF low impedance
ESR : 0.4Ω Max.
Ripple current 0.25Arms or above
Capacitor impedance affects the output ripple voltage.
above 250V, 0.1 to 0.22µF
Use a film or ceramic capacitor
Evaluate under actual operating conditions.
L1: Power Inductor
Inductance : 1.5mH Rating current : above 0.4A
D1: Rectifier diode
In the absolute maximum ratings, the reverse surge voltage should be
400V or above the average rectifier current should be 1A or greater,
and the forward surge current should be 20A or more.
R1: Noise reduction resistor 10 to 22Ω 1/4W
Determine the ideal value through actual testing.
ZNR: Varistor
A varistor must be used to protect against lightning surges and
static electricity.
Dimensions (Unit : mm)
35.0MAX.
9.1MAX.
3.6MAX.
1 35 7
10 12
0 . 5 ±0 . 1
5.08
7.62
1 . 3 ±0 . 2
2.54�11=27.94
0 . 2 5 ±0 . 0 5
4.85MAX.
4.25MAX.
Derating Curve
Derating Curve
250
200
150
100
Operation Range
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=31°C, Vi=141V)
50
100 150 200
Output Current Io(mA)
Load Regulation
Load Regulation
30
(Ta=25°C, Vi=141V)
25
20
15
10
5
0
0 50 100 150 200 250 300
Output Current Io(mA)
Surface Temperature Increase
Surface Temperature Increase
(Ta=315°C, Vi=141V)
40
35
30
25
20
15
10
5
0
0 50 100 150 200 250
Output Current Io(mA)
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1
2010.01 - Rev.A