Data Sheet
100VAC Input/12VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5037B12
Absolute Maximum Ratings
Parameter
Input voltage
Maximum Output current
ESD endurance
Operating temperature range
Storage temperature range
Maximum surface temperature
Symbol
Vi
Iomax
Vsurge
Topr
Tstg
Tcmax
Limits
170
200
2
−25 to +80
−25 to +105
105
Unit
V
mApk
kV
°C
°C
°C
Dimensions (Unit : mm)
28.2MAX.
9.0MAX.
3.3MAX
1
3
5
7
10
5 . 0 8 0 . 5 ±0 . 1
7.62
1 . 3 ±0 . 2
(2.54�9=)22.86 TYP.
0 . 2 5 ±0 . 0 5
5.05MAX.
3.95MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 113 141 170
V DC(80 to 120VAC)
Output voltage
Vo 11.0 12.0 13.0 V Vi=141V, Io=100mA
Output current
Io
0
−
200 mA Vi=141V
∗1
Line regulation
Vr
− 0.05 0.15 V Vi=113 to 170V, Io=100mA
Load regulation
Vl
− 0.07 0.20 V Vi=141V, Io=0 to 100mA
Output ripple voltage Vp
Power conversion efficiency η
− 0.05 0.15 Vp-p Vi=141V, Io=100mA ∗2
70 78
−
% Vi=141V, Io=200mA
Derating Curve
Derating Curve
300
250
200
150
Operation Range
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
Conversion Efficiency
Application Circuit
BP5037B12
Please note that pin No.10
side is input.
10
7
D1
R1
FUSE
1A
1SR35−400 10Ω1/4W
Input
AC100V
50Hz/60Hz
ZNR + C1
C2
220V − 22µF/200V 0.1µF
53
L1
820µH
Pin No.
Function
1 Output terminal Vo(12V)
2 Not used
3 Choke coil connect
4 Not used
5 Choke coil connect
6 Not used
7 COMMON
1
8 Not used
9 Not used
Output
10
+12V
Input terminal Vi(141VDC)
+ C3
− 330µF/25V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: Fuse
Use a quick-acting fuse of 1A
C1: Input smoothing
capacitor
Capacitance : 22 to 100µF Rated voltage : 200V or higher
Ripple current is 0.13Arms or above.
C2: Noise reduction
capacitor
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating
conditions.
C3: Output smoothing
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher,
ESR is 0.25Ω max. Ripple current is 0.4Arms or above.
Evaluate under actual conditions.
D1: Rectifier diode
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used)
Conversion Efficiency
100
(Ta=25°C, Vi=141V)
90
80
70
60
50
40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 200
Output Current Io(mA)
Load Regulation
Load Regulation
14
(Ta=25°C, Vi=141V)
12
10
8
6
4
2
0
0 50 100 150 200 250 300
Output Current Io(mA)
Surface Temperature Increase
Surface Temperature Increase
(Ta=25°C, Vi=141V)
50
40
30
20
10
0
0
50
100
150
200
Output Current Io(mA)
L1: Choke coil
Coil for switching regulator. The inductance should be 820µH,
the rated direct current should be 0.42A or above
in order to prevent excessive heat generation or oscillation.
R1: Noise reduction
resistor
10 to 22Ω 1/4W
The ideal value can be determined through actual testing.
ZNR: Varistor
A varistor must be used to protect against lightning surges and static electricity.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
1/1