Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
195
80
2
−20 ∼ +80
−25 ∼ +85
Unit
V
mApk
kV
°C
°C
Dimension(Unit : mm)
28.2MAX.
10.0MAX.
3.25MAX
1 2 3 45 67 8
0 . 5 ±0 . 1 1 . 3 ±0 . 2
P = 2 . 5 4 ±0 . 2
2.54×9=22.86
10
0.25± 0.05
3.5MAX.
6.5MAX.
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 113 141 195 V DC(80∼138VAC)
Output voltage
Vo
14
15
16
V Vi=141V, Io=80mA
Output current
Io
Line regulation
Vr
Load regulation
Vl
Output ripple voltage Vp
Power conversion effciency η
0
−
80 mA Vi=141V
∗1
− 0.02 0.15 V Vi=113∼195V, Io=80mA
− 0.05 0.15 V Vi=141V, Io=0∼80mA ∗2
− 0.05 0.15 Vp-p Vi=141V, Io=80mA
60 70
−
% Vi=141V, Io=80mA ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion effciency.
Application circuit
Pin No.
Function
BP5034D15
1 Output terminal Vo(15V)
2 N.C.
Please note that pin No.10
side is input.
3 N.C.
4 N.C.
5 COMMON
6 COMMON
7 N.C.
10 8 7 6 5 4 3 2 1
8
9
D1
R1
FUSE
0.5A
Output 10
1SR35−400A 10Ω1/4W
+15V
N.C.
Not used
Input terminal Vi(141VDC)
Input
AC100V
50Hz/60Hz
ZNR + C1
C2
220V − 10µF/250V 0.1µF
+ C3
− 100µF/50V
Be sure to use fuse for safety.
For acutual usage, Please kindly evaluate and confirm our part mounted in your product,
Especially, Please make sure to confirm whether the load current exceed Max. rated current
by using the current probe.
External components setting
FUSE: Fuse
C1: Capacitor for input
voltage smoothing
C2: For noise terminal
voltage reduction
C3: Capacitor for Output
voltage smooting
D1: Rectifier diode
R1: For noise terminal
voltage reduction
ZNR: Varistor
Please make sure to use quick acting fuse 0.5A
Capacitance : 3.3µF∼22µF Rated voltage : 200V or higher
Ripple current is 0.13Arms above.
Capacitance : 0.1µF∼0.22µF Rated voltage : 200V or higher
Film capacitor or ceramic capacitor. Reduce the noise terminal voltage.
The constant value should be evaluated in the set.
Capacitance : 100µF∼470µF Rated voltage : 35V or higher,
ESR is 0.39Ω max. Ripple current is 0.1Arms above.
Output noise voltage is influenced.Please evaluate it in the actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectifier can be used in our part.)
10Ω∼22Ω 1/4W
Reduce the noise terminal voltage.The constant value should be evaluated
in set.
Varistor must be used. It protects this part from lighting surge and static
electricity.
Derating Curve
Derating Curve
90
80
70
60
50
40
30
Operation Range
20
10
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Switching Frequency
Switching Frequency
(Ta=25°C, Vi=141V)
120
100
80
60
40
20
0
0
20
40
60
80
Output Current Io(mA)
Conversion Efficiency
Conversion Efficiency
(Ta=25°C, Vi=141V)
80
70
60
50
60% Min−Line
40
30
20
10
0
0
20
40
60
80
Output Current Io(mA)
Load Regulation
Load Regulation
(Ta=25°C, Vi=141V)
16.0
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
14.0
0
20
40
60
80
Output Current Io(mA)
Surface Temperature Rising
Surface Temperature Rising
(Ta=25°C, Vi=141V)
40
30
20
10
0
0
20
40
60
80
Output Current Io(mA)
1/2