English
Language : 

BP5033-12_10 Datasheet, PDF (1/4 Pages) Rohm – Non-Isolated AC/DC Converter
Data Sheet
100VAC Input/12VDC (100mA) Output
Non-Isolated AC/DC Converter
BP5033-12
Absolute Maximum Ratings
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Symbol
Vi
Io
Vsurge
Topr
Tstg
Limits
170
100
2
−25 to +80
−25 to +105
Unit
V
mApk
kV
°C
°C
Electrical Characteristics
Parameter
Symbol Min. Typ. Max. Unit
Conditions
Input voltage range
Vi 113 141 170 V DC(80 to 120VAC)
Output voltage
Vo 12.0 12.7 13.4 V Vi=141V, Io=50mA
Output current
Line regulation
Io
0
−
100 mA Vi=141V
∗1
Vr
− 0.02 0.1 V Vi=113 to 170V, Io=50mA
Load regulation
Vl
Output ripple voltage Vp
− 0.01 0.15 V Vi=141V, Io=0 to 50mA ∗2
− 0.04 0.15 Vp-p Vi=141V, Io=50mA
Power conversion efficiency η
64 69
−
% Vi=141V, Io=100mA ∗2
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Application Circuit
Pin No.
Function
BP5033-12
Please note that pin No.10
side is input.
1 Output terminal Vo(12V)
2 N.C.
3 N.C.
4 N.C.
5 COMMON
6 COMMON
7 N.C.
10 8 7 6 5 4 3 2 1
8 N.C.
9 Not used
D1
R1
FUSE
0.5A
10Ω1/4W
Output 10
+12V
Input terminal Vi(141VDC)
Input
AC100V
50Hz/60Hz
ZNR + C1
C2
220V − 10µF/250V 0.1µF
+ C3
− 100µF/50V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
FUSE: Fuse
Use a quick-acting fuse of 0.5A
C1: Input smoothing
capacitor
Capacitance : 3.3 to 22µF Rated voltage : 250V or higher
Ripple current is 0.13Arms or above.
C2: Noise reduction
capacitor
Capacitance : 0.1 to 0.22µF Rated voltage : 250V or higher
Use a film or ceramic capacitor. Evaluate under actual conditions.
C3: Output voltage
smoothing capacitor
D1: Rectifier diode
Capacitance : 100 to 470µF Rated voltage : 25V or higher,
ESR is 0.39Ω max. Ripple current is 0.1Arms above.
Evaluate under actual operating conditions.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current 20A or greater.
(Full-wave rectification can be used)
R1: Noise reduction
resistor
ZNR: Varistor
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
A varistor must be used to protect against lighting surges and static
electricity.
Dimensions (Unit : mm)
28.2MAX.
10.5MAX.
1 2 3 45 67 8
0.5±0.1
1.3±0.2
P=2.54±0.2
2.54�9=22.86
10
0.25±0.05
4.25MAX.
6.25MAX.
Derating curve
Derating Curve
120
100
80
60
Operation Range
40
20
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
Conversion Efficiency
(Vi=141V, Ta=25°C )
80
70
60
50
40
30
20
10
0
0 10 20 30 40 50 60 70 80 90 100
Output Current Io(mA)
Load Regulation
Load Regulation
14
(Vi=141V, Ta=25°C)
12
10
8
6
4
2
0
0 50 100 150 200 250
Output Current Io(mA)
Surface Temperature Increase
Surface Temperature Increase
(Vi=141V)
35
30
25
20
15
10
5
0
0 20 40 60 80 100
Output Current Io(mA)
www.rohm.com