English
Language : 

BD6039GU Datasheet, PDF (1/25 Pages) Rohm – Power Supply for CCD Camera Module
System Power Supply ICs for CCD Camera of Mobile Phones
Power Supply
for CCD Camera Module
BD6039GU
No.10033EAT02
●Description
BD6039GU is system power supply LSI for CCD camera that supplies all voltage sources for CCD camera.
This IC has Step up DC/DC converter and LDO for CCD sensor, Inverted DC/DC converter for CCD sensor, and LDO (7ch).
REGA, REG1, REG8, REG5 can be connected the power supply independent from VBAT.
Each output voltage has an adjustable by the register, and this IC can correspond to various CCD modules.
A necessary power supply for CCD camera system is integrated into 1chip, and it contributes to space saving.
BD6039GU achieves compact size with the chip size package.
●Features
1) The BD6039GU is equipped with all voltage sources for CCD camera system.
2) Each output has an adjustable voltage; hence this IC can correspond to various CCD modules.
3) The BD6039GU is controlled by I2C BUS format.
4) The BD6039GU employs 4.8mm2 chip size package, so this IC achieves compact size.
●Functions
1) Step up DC/DC converter and LDO for CCD sensor (+15V/+14.5V/+13V)
2) Inverted DC/DC converter for CCD sensor (-8V/-7.5V/-7V)
3) 7ch Series Regulator
REG1 : 1.2V, Iomax=210mA
REG2 : 3.0V, Iomax=50mA
REG5 : 1.5V/1.8V, Iomax=100mA
REG6 : 3.2V/3.3V, Iomax=260mA
REG7 : 3.0V/3.3V, Iomax=50mA
REG8 : 1.5V/1.8V, Iomax=100mA
REGA : 1.5V/1.8V, Iomax=100mA
4) Correspondence to I2C BUS format
5) Thermal shutdown (Auto-return type)
6) VCSP85H4 chip size package (1.0mm max)
●Absolute Maximum Ratings(Ta=25℃)
Parameter
Maximum Applied voltage 1
Maximum Applied voltage 2
Maximum Applied voltage 3
Maximum Applied voltage 4
Power Dissipation
(Note 1)
(Note 2)
(Note 3)
(Note 4)
(Note 5)
Symbol
VMAX1
VMAX2
VMAX3
VMAX4
Pd
Operating Temperature Range
Topr
Storage Temperature Range
Tstg
(Note 1)
(Note 2)
(Note 3)
(Note 4)
(Note 5)
SWP, VPLUS1, VPLUS2 pin
VDD3 pin
VDD4, SWN pin
Except Note1~Note3 pin
Power dissipation deleting is 16.9mW/ ℃, when it’s used in over 25℃.
(It’s deleting is on the board that is ROHM’s standard)
Ratings
20
18
-13.5
6
2110
-30 ~ +85
-55 ~ +150
Unit
V
V
V
V
mW
℃
℃
●Recommended Operating Conditions (VBAT≥VIO, Ta=-30~85 ℃)
Parameter
Symbol
Limits
Unit
VBAT input voltage
VBAT
2.7 ~ 5.5
V
VIO pin voltage
VIO
1.65 ~ 3.3
V
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
1/24