3MDC10113 Datasheet, PDF (3/8 Pages) RMT Ltd. – Blank ceramics (not metallized) | |||
|
◁ |
Thermoelectric Cooling Solutions
Performance Data
@ 27ºC, Vacuum
ÎTmax
K
3MDC10-113-10AN 107
Qmax
W
4.52
Imax
A
3.1
Umax
V
8.3
3MDC10-113-10AN
@50ºC, N2
ÎTmax
K
3MDC10-113-10AN 103
Qmax
W
5.13
Imax
A
3.3
Umax
V
9.5
Note: Performance data is speciï¬ed at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.
Performance Data
@ 27ºC, Vacuum
ÎTmax
K
3MDC10-113-15AN 108
Qmax
W
3.12
Imax
A
2.2
Umax
V
8.3
3MDC10-113-15AN
@50ºC, N2
ÎTmax
K
3MDC10-113-15AN 99
Qmax
W
3.53
Imax
A
2.3
Umax
V
9.5
! Note: Performance data is speciï¬ed at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2013. RMT Ltd. The design and speciï¬cations of products can be changed by RMT Ltd without notice.
Page 3" of 8"
|
▷ |