English
Language : 

2MP04-060 Datasheet, PDF (3/4 Pages) RMT Ltd. – Specifications
2MP04-060 Series
2MP04-060-15
RMT Ltd.
Standard Perfomance Plots
100
90
80
70
60
50
40
30
20
10
0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
Current, A
3.5
3.0
2.5
2.0
1.5
Imax
1.0
0.8 Imax
0.5
0.6 Imax
0.4 Imax
0.0
0 10 20 30 40 50 60 70 80 90 100
DT, K
100
90
80
70
60
50
40
30
20
10
0
0.0
Imax
0.8 Imax
0.6 Imax
0.4 Imax
0.5
1.0
1.5
Q, W
1.5
1.0
0.5
0.0
0 10 20 30 40 50 60 70 80 90 100
DT, K
Application tips
Cautions
1. Never heat TE module more than 160oC (TEC assembled
at 183oC) or 200oC (TEC assembled at 230oC).
2. Never use TE module without attached heat sink at
hot (bottom) side.
Installation
3. Connect TE module to DC power supply according to
polarity
4. Do not apply DC current higher than Imax.
1. Mechanical Mounting
TEC is placed between two heat exchangers . This construction is fixed by screws or in
another mechanical way.
It is suitable for large modules (with dimensions 30mmx30mm and larger). Miniature types
require other assembling methods.
2. Soldering
This method is suitable for a TE module with metallized outside surfaces (cold and hot
sides). RMT provides this option and also makes pre-tinning for TE modules. In comparison
with a mechanical assembling method, soldering requires careful procedures.
3. Glueing
It is an up-to-date method that is used by many customers due to availability of glues with
good thermoconductive properties. A glue is usually based on some epoxy compound filled
with some thermoconductive material such as graphite or diamond powders, silver, SiN and
others. The application of a specific type depends on application features and the type of a
TE module.
53 Leninskij prosp. Moscow 119991 Russia, phones: 7-095-132-6817, 7-095-132-6685, fax: 7-095-132-5870, e-mail: rmtcom@dol.ru
Copyright 2005. RMT Ltd. The design and specifications of products can be changed by RMT Ltd. without notice.
429
RMTK 187.00.00