RT9711 Datasheet, PDF (4/15 Pages) Richtek Technology Corporation – 80mΩ, 1.5A High-Side Power Switches with Flag
RT9711
Preliminary
Parameter
FLAG Delay Time (Note 4)
Under-Voltage Lockout
Under-Voltage Hysteresis
Thermal Shutdown Protection
Thermal Shutdown Hysteresis
Symbol
Test Conditions
tD
VUVLO
ΔVUVLO
TSD
ΔTSD
From fault condition to FLG
VIN increasing
VIN decreasing
Min Typ Max Units
5
12 20 ms
1.3 1.7 --
V
-- 0.1 --
V
-- 130 --
°C
--
20
--
°C
Note 1. Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
Note 2. Devices are ESD sensitive. Handling precaution recommended.
Note 3. The device is not guaranteed to function outside its operating conditions.
Note 4. The FLAG delay time is input voltage dependent, see“ Typical Operating Characteristics” graph for further details.
Note 5. θJA is measured in the natural convection at TA = 25°C on a low effective single layer thermal conductivity test board of
JEDEC 51-3 thermal measurement standard.
www.richtek.com
4
DS9711-04 March 2007