English
Language : 

AKL Datasheet, PDF (2/3 Pages) Altech corporation – Polystyrene and Polycarbonate - 150x300mm (5.91x11.81in.)
Specifications:
AKL Sensors
Property
Input Voltage
Supply Current in Off State
Min
Typ
Max
Unit
4.5
48
Volts1
3.2
4.0
4.8
mA2
(Input Voltage=12V)
Supply Current in On State
7.0
8.0
9.0
mA2
(Input Voltage=12V)
Output Duty Cycle
40
50
60
%
Operating Temperature Range
-40
+150 °C
AKL001-12 Airgap, Over Full Temperature and
1.0
Voltage Range4
3.5 mm
AKL002-12 Airgap, Over Full Temperature and
1.0
Voltage Range4
2.5 mm
Frequency of Operation
ESD
0
10K Hz
2000
V3
Absolute Maximum Ratings
Parameter
Limit
Supply Voltage
60V
Reverse Battery Voltage
-60V
Continuous Output Current
16mA
Junction Temperature Range
-40°C to +175°C
Storage Temperature Range
-65°C to +200°C
10
Current
Output
5
(mA)
Signal Output
Time
Notes:
1. The supply voltage must appear across the power and ground terminals of the part. Any
additional voltage drop due to the presence of a series resistor is not included in this
specification.
2. Supply currents can be factory programmed to different levels, for example 3mA and 6mA, or
7mA and 14mA; contact NVE for details.
3. Pin to pin voltage, Human Body Model for ESD
4. Airgap measured with standard ferrous gear tooth, contact NVE for details.
IC Drawings:
The AKL Series products use the ABL sensor elements described earlier in this section.
The AKL001-12 part uses the ABL004 sensor element, the AKL002-12 uses the ABL005
sensor element, and the AKL003-12 uses the ABL006 sensor element. Please see the IC
drawings in the ABL series section for more information.
RHOPOINT COMPONENTS
Tel: +44 (0) 870 608 1188 Fax: +44 (0) 870 241 2255
Web: www.rhopointcomponents.com Email: sales@rhopointcomponents.com