English
Language : 

ULV60 Datasheet, PDF (1/2 Pages) RHOPOINT COMPONENTS – ULV/ULH TYPE
Tel : + 44 (0) 1883 717988
Fax : +44 (0) 1883 712938
/
ULV/ULH TYPE (UL® Approved)
The ULV(V=vertical & ULH(H=horizontal) models are UL approved metal-clad, wire-wound high-power resistors designed for
industrial and other applications. Our extruded aluminium housing provides rugged and strong protection. These models are
available with flying leads or Tab terminals and can be ordered with inductive or non-inductive windings. To conform to UL
safety requirements, ULV/ULH models differ from IRV/IRH models in that: The resistance range is smaller, the flying leads
are UL approved and the dielectric strength depends on the ohmic value.
GENERAL SPECIFICATIONS
Model
ULH/ULV60
ULH/ULV80
ULH/ULV100
ULH/ULV120
ULH/ULV150
ULH/ULV200
ULH/ULV300
ULH/ULV400
ULH/ULV500
Wattage
Rating
on
Heat Sink
60
80
100
120
150
200
300
400
500
Resistance Range [ohms]
Inductive
Tab
terminals
0.1-375
0.1-281
0.1-225
0.1-187
0.1-150
0.1-450
0.1-300
0.1-225
0.1-180
Flying
leads
0.1-400
0.1-910
0.1-1.1K
0.1-1.3K
0.1-1.6K
0.1-2.2K
0.1-2.7K
0.1-4.3K
0.1-6.8K
Non-
Inductive
Tab
terminals
Flying
leads
0.1-180
0.1-180
0.1-110
0.1-110
0.1-225
0.1-240
0.1-187
0.1-300
0.1-150
0.1-390
0.1-450
0.1-1K
0.1-300 0.1-1.5K
0.1-225 0.1-2.2K
0.1-180
0.1-3K
Resistance
Tolerance
+-2.0(G)
+-5.0(J)
+-10(K)
CHARACTERISTICS
Temperature Range
Values in [ ] mean change in ohms after test
-55C to 200C
Insulation Resistance
20M ohms minimum
Dielectric Strength
[1000V+(rated voltage×2)] / min.
Temp. Coefficient
+-260ppm/C maximum
Short Time Overload
+-[2%+0.05ohms] 60W:5Xwattage rating-5second, 80to500W: 10Xwattage rating-5seconds
Moisture Resistance
+-[3%+0.05 ohms]
40C, 95% RH, DC100V case to terminal (500hrs.)
Thermal Shock
+-[2%+0.05 ohms]
wattage rating 30min., -25C, 15minutes
Vibration
+-[1%+0.05 ohms]
10Hz-55Hz-10Hz (1min.),2hrs. each direction
Moisture Load Life
+-[3%+0.05 ohms]
40C,95%RH,0.1Xwattage rating, 1.5h.on,30min.off,500 hours
Load Life
+-[5%+0.05 ohms]
Wattage rating 1.5h. on, 30min. off, 500hours
Applied voltage : AC RMS voltage
SURFACE TEMPERATURE INCREASE VERSUS POWER LOAD
A mid-point bracket is required for 150, 300, 500W models to ensure sufficient contact with the heat sink.
Website : http://www.rhopointcomponents.com Email: sales@rhopointcomponents.com