English
Language : 

CPT1000 Datasheet, PDF (1/1 Pages) RHOPOINT COMPONENTS – Platinum Temperature Sensor SMD 1206 CPT 1000
Platinum Temperature Sensor SMD 1206 CPT 1000
Technical Data
Resistance at 0°C
1000 Ω
Temperature coefficient
(0°C up to 100°C)
3.85 · 10-3 K-1
Tolerance class to DIN EN 60751 B
Operating temperature range
-50 °C up to 150 °C
Measurement current (DC)
at 25 °C
0.1 mA
Maximal permissible peak current
(DC) at 25 °C
0.3 mA
Insulation resistance
> 10 MΩ
Self-heating at 0 °C
< 0.4 K / mW
Thermal response time
Flowing water (v = 0.2 m/s)
Flowing air (v = 1 m/s)
T0.5 = 0.2 s
T0.9 = 0.5 s
T0.5 = 4 s
T0.9 = 10 s
Resistance value
(Class B) at
0 °C
1000.00 Ω ± 1.2 Ω
100 °C 1385.10 Ω ± 3.0 Ω
Maximal Resistance Change
at UCT 250 h
< 0.1 %
Construction
SMD 1206
Specification
DIN EN 60751
Technology
Advanced thin-film-technology (ceramic carrier with
a structured platinum layer, covered with a
passivating layer)
Conformity
2002/95/EC Restriction of the use of Hazardous
Substances Directive (RoHS)
Dimensions [mm]
0.5 ± 0.25
Protective layer
Solder joint
Ceramic carrier
0.5 ± 0.25
3 + 0.35
- 0.1
Revision
07/01
Functional performance
according to DIN EN 60751
± 5,0
± 4,0
± 3,0
Class B [Ω]
Class B [°C]
± 2,5
± 2,0
± 1,5
± 2,0
± 1,0
± 1,0
± 0,5
± 0,0
-50
0
50
100
Temperature [°C]
± 0,0
150
Picture 1: Resistance and temperature tolerances of CPT 1000 B
Temperature range of -50 °C up to 0 °C:
Rt = Ro · (1 + A · t + B · t2 + C · (t – 100 °C) · t3)
Temperature range of 0°C up to 150°C:
Rt = Ro · (1 + A · t + B · t2 )
Tolerance class B to DIN EN 60751:
∆t = ± (0.3 + 0.005 · | t |)
Whereby:
Rt … Resistance [Ω] at temperature t
Ro … Resistance [Ω] at 0 °C
t … Temperature [°C]
∆t … Permissible temperature deviation at t [°C]
A = 3.9083 · 10-3 °C-1
B = - 5.775 · 10-7 °C-2
C = - 4.183 · 10-12 °C-4
Fields of application
• Industrial electronics
• Automotive electronics
• Energy and environmental engineering
Ordering information
Please use the following code:
Type
Class of Construction Temperature
accuracy
range [°C]
Code CPT 1000 B SMD 1206 -50/150
Other classes of accuracy available on request
Made in Germany
© UST Umweltsensortechnik GmbH 2006
Subject to alterations for this information and technological changes
UST Umweltsensortechnik GmbH
Dieselstr. 2, 98716 Geschwenda, Germany
Phone +49 36205 713-0 info@umweltsensortechnik.de
Fax +49 36205 713-10 www.umweltsensortechnik.de