English
Language : 

T-966 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T1/CEPT PULSE TRANSFORMER
T1/CEPT PULSE TRANSFORMER
Turns Ratio ( + 5% )
1 :1
PARAMETER
MIN.
TYP.
MAX.
Open Circuit Inductance
3.5
5
6.5
Primary DC Resistance
1.0
Secondary DC Resistance
1.0
Isolation (HI-POT)
1.5
TEST CONDITIONS:
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz
Inductance measured on Primary winding. Pins 1 - 4. with 2-3 shorted.
UNITS
mHy
ohms
ohms
KVRMS
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Temperature Characteristics:
-40o C 3 mH min. (40% drop in
inductance)
+85o C 5.75 mH min. (15% growth
in inductance)
Typical part:
5 mH @ +25o C
5.75 mH @ +85o C
3.5 mH @ -40o C
Parts shipped in anti-static
tubes. 44 pieces per tube
Tape & Reel
Available
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
Top view
87 6 5
1 234
Rhombus
Industries Inc.
Transformers & Magnetic Products
.410
(10.41)
MAX.
.410
(10.41)
MAX.
.020
(0.51)
TYP.
.100
(2.54)
TYP.
.260
(6.60) .300
MAX. (7.62) .010
MAX. (0.25)
TYP.
.040
(1.02)
TYP.
.510 (12.95)
.480 (12.19)
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-966
CUST P/N:
NAME:
DATE: 11/12/99
SHEET: 1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971