English
Language : 

T-927 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – MULTI -PURPOSE TRANSFORMER
MULTI -PURPOSE TRANSFORMER
Turns Ratio ( + 2% )
PARAMETER
Open Circuit Inductance
Leakage Inductance
Interwinding Capacitance (CW/W)
Primary DC Resistance
Secondary DC Resistance
Isolation (HI-POT)
ET Product
MIN.
5.0
1.5
175
1:1
NOM.
6.0
110
60
10.4
11.8
500
UNITS
mHy
µHy
pF
ohms
ohms
KVRMS
VµS
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Temperature Characteristics:
-55o C 4.35 mH nom. (13% drop in
inductance)
+125o C 4.75 mH nom. (5% drop in
inductance)
Typical part:
6.0 mH @ +25o C
5.7 mH @ +125o C
5.22 mH @ -40o C
TEST CONDITIONS:
Oscillation Voltage = 1 VRMS
Oscillation Frequency = 100.0 KHz
Inductance measured on Primary winding. Pins 1 - 2.
Parts shipped in anti-static
tubes. 26 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM:
UNUSED PINS OMITTED
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-927
CUST P/N:
NAME:
DATE: 6/23/97
SHEET: 1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971