English
Language : 

T-50122 Datasheet, PDF (1/1 Pages) List of Unclassifed Manufacturers – MULTI-PURPOSE PULSE TRANSFORMER
Turns Ratio ( + 5% )
2CT : 1CT
PARAMETER
MIN.
MAX.
UNITS
Open Circuit Inductance
20
µHy
Leakage Inductance
1.5
µHy
Interwinding Capacitance (CW/W)
Primary DC Resistance
12
pF
1.3
ohms
Secondary DC Resistance
1.3
ohms
Primary ET-Constant
5.8
Vµs
Rise Time
7.5
nS
Isolation (HI-POT)
500
VRMS
Average Power Rating
Dissipation Rating
Peak Pulse Voltage
Insulation Resistance
500 mW
150 mW
100 volts
10,000 MΩ
TEST CONDITIONS:
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz TESTED WITH AN H.P. 4192A
PHYSICAL DIMENSIONS
All dimensions in inches (mm)
MULTI-PURPOSE
PULSE
TRANSFORMER
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 50 pieces per tube
SCHEMATIC DIAGRAM
5
6
3
4
1
2
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-50122
CUST P/N:
NAME:
DATE: 07/02/98
SHEET: 1 OF 1
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971