English
Language : 

T-31204 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – HYBRID Transformer
Electrical Specifications at 25OC
Parameter
Impedance
PRI.
Units
600
Ω
SEC.
150/150 Ω
Turns Ratio Prim. : Sec.
1:1
Direct Current in Pri. (DCI)
maximum
30
mA
DC Resistance
PRI. + 10%
50
Ω
SEC. + 10%
20+20 Ω
Insertion Loss
max., ref. 1 kHz
1.2
dB
Longitudinal Balance
300-3500 Hz
>65
dB
Frequency Response
max., 300 to 3500 Hz + 1.5
dB
Return Loss
ref. 1.8 kHz
>18
dB
Isolation
minimum
1500
V
RMS
Physical Dimensions
inches (mm)
HYBRID
Transformer
Schematic
Diagram
1
Pri.
6
2
5Sec.
3
4
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-31204
CUST P/N:
NAME:
DATE: 01/09/02
SHEET:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971