English
Language : 

T-14961 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – 10BASE T ISOLATION TRANSFORMER
10BASE T ISOLATION TRANSFORMER
Electrical Specifications at 25OC
Turns Ratio +5%
1CT : 1.41CT (Pins 6-8:11-9)1
1CT : 1CT (Pins 1-3:16-14)2
PARAMETER
Open Circuit Inductance (1-3)
@ 100 kHz-20mV
Open Circuit Inductance (6-8)
@ 100 kHz-20mV
Leakage Inductance (1-3, Short 16-14)
@ 100 kHz-20mV
Leakage Inductance (6-8, Short 11-9)
@ 100 kHz-20mV
MIN.
110
110
MAX.
0.4
0.4
UNITS
µH
µH
µH
µH
Interwinding Capacitance
@ 100 kHz-20mV (1-3 to 14-16)
Interwinding Capacitance
@ 100 kHz-20mV (6-8 to 11-9)
DC Resistance Primary
HI-POT
15
15
1.0
1500
pF
pF
ohms
VRMS
1. Transmit
2. Receive
Dimensions in inches (mm)
Fast Rise Times
Meets ECMA Requirements
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
SCHEMATIC DIAGRAM
RECEIVE
1
16
2
15
3
14
TRANSMIT
6
13
11
7
10
8
12
9
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-14961
CUST P/N:
NAME:
DATE: 12/10/01
SHEET: 1 OF 1
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971