English
Language : 

T-14959 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – 10BASE T ISOLATION TRANSFORMER
10BASE T ISOLATION TRANSFORMER
Turns Ratio +5%
1CT : 1CT (Pins 1-3:16-14)1
1CT : 2.5CT (Pins 6-8:11-9)2
PARAMETER
MIN.
Open Circuit Inductance (1-3)
200
@ 100 kHz-20mV
Open Circuit Inductance (6-8)
200
@ 100 kHz-20mV
Leakage Inductance (1-3, Short 16-14)
@ 100 kHz-20mV
Leakage Inductance (6-8, Short 11-9)
@ 100 kHz-20mV
Interwinding Capacitance
@ 100 kHz-20mV (1-3 to 14-16)
Interwinding Capacitance
@ 100 kHz-20mV (6-8 to 11-9)
DC Resistance Primary
HI-POT
2000
Operating Temperature Range -400C to +850C
1 Receive
2 Transmit
MAX.
0.5
0.5
15
15
0.4
UNITS
µH
µH
µH
µH
pF
pF
ohms
VRMS
Fast Rise Times
Meets ECMA Requirements
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
SCHEMATIC DIAGRAM
1
16
2
15
3
14
Dimensions in inches (mm)
6
11
7
10
8
9
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-14959
CUST P/N:
NAME:
DATE: 07/02/01
SHEET: 1 OF 1
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971