English
Language : 

T-1484 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – DC DC Converter Transformer
DC DC Converter Transformer
(For Use with Maxim MAX253 & MAX845)
Turns Ratio ( + 3% )
1CT : 1CT
PARAMETER
MIN.
MAX.
UNITS
Open Circuit Inductance
768
1152
mHy
Leakage Inductance
0.7
µHy
Rise Time
10
nSec
DC Resistance
0.8
ohms
Isolation (HI-POT)
ET Product
2.0
KVRMS
11
VµS
Interwinding Capacitance
35
pF
TEST CONDITIONS: Oscillation Voltage = 100mV, Oscillation Frequency = 100.0 KHz
Primary pins 1-4, short 2&3
Flammability: Materials used in the
production of these units meet
requirements of UL94-VO and IEC
695-2-2 needle flame test.
Operating Temperature
Range: -400C to +850C
Parts shipped in anti-static tubes.
44 pieces per tube
Tape & Reel Available
SCHEMATIC
DIAGRAM
1
8
8765
2
PRI
3
7
SEC
6
.475
(12.07)
MAX.
Dimensions
in Inches (mm)
4
5
SUGGESTED PAD LAYOUT
.640
(16.26)
.100
(2.54)
TYP.
.050
(1.27)
TYP.
.100
(2.54)
TYP.
Rhombus
Industries Inc.
Transformers & Magnetic Products
123
.430
(10.92)
MAX.
4
.260
(M6.A6X0.)(.73.0602)
MAX.
.025
(0.64)
TYP.
.100
(2.54)
TYP.
.410
(10.41)
.030
(0.76)
TYP.
.600 (15.24)
.580 (14.73)
.010
(0.25)
TYP.
RHOMBUS INDUSTRIES INC.
FSCM NO. 16714
RHOMBUS P/N: T-1484
CUST P/N:
NAME:
DATE: 02/28/02
SHEET: 1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com