English
Language : 

T-1482 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – 10BASE-T INTERFACE TRANSFORMER
10BASE-T INTERFACE TRANSFORMER
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio ( + 5% )
Parameter
Open Circuit Inductance
Leakage Inductance
Interwinding Capacitance (CW/W)
Primary DC Resistance
Secondary DC Resistance
Isolation (HI-POT)
Min.
200
4000
1CT:1CT
Max.
0.8
15
0.4
0.5
Units
µH
µH
pF
ohms
ohms
VRMS
Meets IEE 802.3 and ANSI X3.263
Standards.
Transformer can be used for Transmit
or Receive side.
Flammability: Materials used in the
production of these units meet
requirements of UL94-VO and IEC
695-2-2 needle flame test.
0.5mm minimum insulation thickness
between primary and secondary.
Parts shipped in anti-static tubes.
31 pieces per tube
OPERATING TEMPERATURE RANGE:
-400C TO +850C
Physical Dimensions
inches (mm)
Schematic Diagram
Leads are #22 AWG solderable
PRELIMINARY!
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-1482
CUST P/N:
NAME:
DATE: 10/05/01
SHEET: 1 OF 1
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971