English
Language : 

T-1417 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – Transformer
Transformer
Turns Ratio
Parameter
Inductance 1-5 1
Leakage Inductance 2
DC Resistance (1-4)
DC Resistance (2-5)
Current
Insertion Loss @28kHz
Frequency Response
@10kHz-300kHz, 28kHz Ref.
Hi-Pot Primary to Secondary
1 : 1 +1%
Min. Typ. Max. Units
1.6
mH
11
µH
1.26
Ω
1.25
Ω
60
mA
0.50 dB
+0.5 dB
1500
VRMS
1..Tested at 20 kHz and 100 mV
2..Pins 1-5, and 10-6 Shorted.
Tested at 100kHz - 100 mV.
Dimensions in Inches (mm)
.522
(13.26)
MAX.
.532
(13.51)
MAX.
.516
(13.1)
MAX.
.100
(2.54)
.028
(0.70)
.025
(0.64)
.516
(13.1)
.675 (17.15)
.663 (16.85)
Schematic Diagram
1
10
5
6
Designed to meet UL1950
(Double Insulation)
Materials used in construction of this
component meet or exceed UL Class B
and can be operated up to 130oC
.715
(18.15)
1
10
2
9
Suggested
Pad Layout
3
8
4
7
5
6
.100
(2.54)
TYP.
.100
(2.54)
TYP.
.050
(1.27)
TYP.
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUSP/N: T-1417
CUST P/N:
DATE: 10/27/99
NAME:
SHEET:
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971