English
Language : 

T-1416 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – Line Transformer
Line Transformer
Turns Ratio
4 : 1 + 1%
Parameter
Inductance 1-5 (2-4, Shorted) 1
Leakage Inductance 2
DC Resistance (1-4)
DC Resistance (2-5)
DC Resistance (9-7)
Hi-Pot Primary to Secondary
Total Harmonic Distortion
@40 kHz, 12 Vp-p ( Pri:Sec.)
Insertion Loss @100kHz
Frequency Response
@40kHz-300kHz, 100kHz Ref.
Longitudinal Balance @
@40kHz-300kHz.
Min.
1.88
Typ.
2.00
2050
50
1..Tested at 10 kHz and 100 mV
2..Pins 1-5, 2-4 shorted, and 9-7 Shorted.
Tested at 100kHz - 100 mV.
Max.
2.12
11
1.26
1.25
1.00
-80
Units
mH
µH
Ω
Ω
Ω
VRMS
dB
0.75 dB
+0.25 dB
dB
Schematic Diagram
1
4
Pri.
2
5
(Line Side)
9
Sec.
7
(Chip Side)
Designed to meet UL1950
(Double Insulation)
Dimensions in Inches (mm)
.522
(13.26)
MAX.
.532
(13.51)
MAX.
.516
(13.1)
MAX.
.100
(2.54)
.028
(0.70)
.025
(0.64)
.516
(13.1)
.675 (17.15)
.663 (16.85)
Materials used in construction of this
component meet or exceed UL Class B
and can be operated up to 130oC
.715
(18.15)
1
10
2
9
Suggested
Pad Layout
3
8
4
7
5
6
.100
(2.54)
TYP.
.100
(2.54)
TYP.
.050
(1.27)
TYP.
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUSP/N: T-1416
CUST P/N:
DATE: 10/27/99
NAME:
SHEET:
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971