English
Language : 

T-14114 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T1/CEPT/ISDN PRI Interface Transformer
T1/CEPT/ISDN PRI Interface Transformer
Electrical Specifications @ 250C
Turns Ratio ( + 3% )
*1:1:1.15:1.26 & 1:2CT
PARAMETER
OCL (Primary)
Leakage Inductance
Capacitance (CW/W)
Primary DC Resistance
MIN.
1.5 & 1.5
MAX.
0.5 & 0.5
35 & 35
0.7 & 0.7
UNITS
mH
µH
pF
Ohms
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
Secondary DC Resistance
1.0 & 1.4
Ohms
Operating Temp Range
Primary Pins 14-16 & 6-8
*Pins 14-16 to 3-4 = 1:1
Pins 14-16 to 2-4 = 1.15
Pins 14-16 to 1-4 = 1.26
-40
+85
0C
Isolation 2000 V Min.
RMS
PHYSICAL DIMENSIONS
inches (mm)
Schematic Diagram
Rhombus
Industries Inc.
Transformers & Magnetic Products
Rhombus P/N: T-14114
Cust. P/N:
Name:
Date: 2/12/98
Sheet:
1 of 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971