English
Language : 

T-14068 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – 10BASE T ISOLATION TRANSFORMER
10BASE T ISOLATION TRANSFORMER
Turns Ratio +2%
1CT:1CT (Pins 1-3:16-14)
1CT:2CT (Pins 6-8:11-9)
PARAMETER
MIN.
Open Circuit Inductance
140
Oscillation Voltage = 100mV
25
Oscillation Frequency = 100.0 KHz
Leakage Inductance
Oscillation Level = 100mV
Oscillation Frequency = 100.0 KHz
Interwinding Capacitance (CW/W)
Oscillation Frequency = 100.0 KHz
Primary DC Resistance
Secondary DC Resistance
High Potential Test
2 Kv
MAX.
0.4
15
0.3
0.3
UNITS
µHy
µHy
µHy
pF
ohms
ohms
VRMS
High Isolation 2000Vrms
Fast Rise Times
Meets ECMA Requirements
IEEE 802.3 Compatible
(10BASE 2, 10BASE 5, & 10BASE T)
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 33 pieces per tube
PHYSICAL DIMENSIONS
All dimensions in inches (mm):
SCHEMATIC DIAGRAM
16 15 14 13 12 11 10 9
1234567 8
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-14068
CUST P/N:
NAME:
DATE: 07/02/99
SHEET: 1 OF 1
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971