English
Language : 

T-13111G Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T3 INTERFACE TRANSFORMER
*T3 INTERFACE TRANSFORMER
Turns Ratio ( + 2% )
1 : 1CT
PARAMETER
Inductance
Leakage Inductance
Capacitance (CW/W)
Primary DC Resistance
1Isolation
MIN.
160
3000
TYP.
MAX.
1.2
5.0
0.6
UNITS
µHy
µHy
pF
ohms
VRMS
Reinforced insulation
* Also suitable for DS3, E3 and STS-1 interfaces
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
Parts shipped in anti-static
tubes. 44 pieces per tube
Tape & Reel
Available
5
6
3
4
Dimensions in inches (mm)
1
2
.410
(10.41)
MAX.
SCHEMATIC DIAGRAM
.020
(0.51)
TYP.
.100
(2.54)
TYP.
.260
(6.60)
MAX.
.300
(7.62)
MAX.
.010
(0.25)
TYP.
.410
(10.41)
MAX.
.040
(1.02)
TYP.
.510 (12.95)
.480 (12.19)
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-13111G
CUST P/N:
NAME:
DATE: 6/04/99
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971