T-13101 Datasheet, PDF (1/1 Pages) Rhombus Industries Inc. – T3 Interface Transformer
Turns Ratio ( + 3% )
T3 Interface Transformer
Also suitable for DS3, E3 and STS-1 interfaces
1:2CT
PARAMETER
Inductance
MIN.
19
MAX.
UNITS
µHy
Rise Time
3.0
nS
Leakage Inductance
0.14
µHy
Capacitance (CW/W)
Primary DC Resistance
15
pF
0.2
ohms
Isolation
1500
VRMS
3 dB Bandwidth is .200 - 340 (MHz) typical, tested in a 75 ohm system
Flammability: Materials used in
the production of these units
are UL94-VO and meet require-
ments of IEC 695-2-2 needle
flame test.
Parts shipped in anti-static
tubes. 55 pieces per tube
Tape & Reel Available
Dimensions in inches (mm)
Schematic Diagram
1
6
2
5
3
4
Rhombus
Industries Inc.
Transformers & Magnetic Products
RHOMBUS P/N: T-13101
CUST P/N:
NAME:
DATE: 4/27/99
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
www.rhombus-ind.com
FAX: (714) 896-0971